Heavy-Duty 6kV Power Cable with Copper Conductor and XLPE Insulation, Protected by Steel Wire Armouring is a robust and reliable solution for transmitting electrical power in demanding environments.
The Heavy-Duty 6kV Power Cable with Copper Conductor, XLPE Insulation, and Steel Wire Armouring typically complies with international and regional standards to ensure safety, reliability, and performance. Below are some of the key standards that such cables often adhere to:
IEC (International Electrotechnical Commission):
IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1.2 kV) up to 30 kV (Um = 36 kV).
IEC 60228: Conductors of insulated cables (specifies conductor classes and requirements).
IEC 60332: Tests for vertical flame propagation for insulated cables.
IEC 60754: Test on gases evolved during combustion of materials from cables.
ISO (International Organization for Standardization):
ISO 9001: Quality management systems (for manufacturing processes).
3.6/6(7.2)kV,XLPE Insulated Unarmored PVC Sheathed Power Cable
Single-core,CU/XLPE/PVC or AL/XLPE/PVC (Table 19)
Conductor Nominal Area | Insulation Thickness | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||
mm² | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.8 | 15 | 320 | 260 | 500 |
16 | 2.5 | 1.8 | 18 | 390 | 290 | 500 |
25 | 2.5 | 1.8 | 20 | 500 | 340 | 500 |
35 | 2.5 | 1.8 | 21 | 610 | 400 | 500 |
50 | 2.5 | 1.8 | 22 | 750 | 450 | 500 |
70 | 2.5 | 1.8 | 24 | 970 | 550 | 500 |
95 | 2.5 | 1.8 | 25 | 1,250 | 660 | 500 |
120 | 2.5 | 1.8 | 27 | 1,500 | 760 | 500 |
150 | 2.5 | 1.8 | 28 | 1,790 | 860 | 500 |
185 | 2.5 | 1.9 | 30 | 2,150 | 1,000 | 500 |
240 | 2.6 | 1.9 | 33 | 2,770 | 1,250 | 500 |
300 | 2.8 | 2.0 | 35 | 3,400 | 1,500 | 500 |
400 | 3.0 | 2.1 | 39 | 4,280 | 1.850 | 500 |
500 | 3.2 | 2.2 | 43 | 5,400 | 2,280 | 500 |
630 | 3.2 | 2.4 | 47 | 6,830 | 2,800 | 500 |
800 | 3.2 | 2.5 | 51 | 8,570 | 3,400 | 400 |
1,000 | 3.2 | 2.6 | 56 | 10,590 | 4,110 | 300 |
Three-core,CU/XLPE/PVC or AL/XLPE/PVC (Table 20)
Conductor Nominal Area | Insulation Thickness | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||
mm² | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.9 | 33 | 980 | 790 | 500 |
16 | 2.5 | 2.0 | 35 | 1,190 | 890 | 500 |
25 | 2.5 | 2.1 | 38 | 1,560 | 1,080 | 500 |
35 | 2.5 | 2.2 | 40 | 1,930 | 1,270 | 500 |
50 | 2.5 | 2.3 | 43 | 2,370 | 1,480 | 500 |
70 | 2.5 | 2.4 | 47 | 3,110 | 1,820 | 500 |
95 | 2.5 | 2.5 | 51 | 4,000 | 2,200 | 500 |
120 | 2.5 | 2.6 | 54 | 4,820 | 2,550 | 500 |
150 | 2.5 | 2.7 | 58 | 5,770 | 2,970 | 500 |
185 | 2.5 | 2.8 | 61 | 6,960 | 3,460 | 500 |
240 | 2.6 | 3.0 | 68 | 8,940 | 4,340 | 400 |
300 | 2.8 | 3.2 | 73 | 10,980 | 5,190 | 300 |
400 | 3.0 | 3.5 | 81 | 13,820 | 6,440 | 250 |
500 | 3.2 | 3.7 | 90 | 17,390 | 7,910 | 200 |
3.6/6(7.2)kV,XLPE Insulated Wire Armored PVC Sheathed Power Cable
Single-core,CU/XLPE/AWA/PVC orAL/XLPE/AWA/PVC (Table 21)
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.2 | 0.9 | 1.8 | 22 | 610 | 550 | 500 |
16 | 2.5 | 1.2 | 1.6 | 1.8 | 24 | 680 | 580 | 500 |
25 | 2.5 | 1.2 | 1.6 | 1.8 | 25 | 810 | 660 | 500 |
35 | 2.5 | 1.2 | 1.6 | 1.8 | 26 | 940 | 730 | 500 |
50 | 2.5 | 1.2 | 1.6 | 1.8 | 27 | 1,100 | 810 | 500 |
70 | 2.5 | 1.2 | 1.6 | 1.8 | 29 | 1,350 | 930 | 500 |
95 | 2.5 | 1.2 | 1.6 | 1.9 | 31 | 1,670 | 1,080 | 500 |
120 | 2.5 | 1.2 | 1.6 | 1.9 | 32 | 1,950 | 1,200 | 500 |
150 | 2.5 | 1.2 | 1.6 | 2.0 | 34 | 2,270 | 1,350 | 500 |
185 | 2.5 | 1.2 | 2.0 | 2.1 | 37 | 2,770 | 1,620 | 500 |
240 | 2.6 | 1.2 | 2.0 | 2.2 | 40 | 3,440 | 1,930 | 500 |
300 | 2.8 | 1.2 | 2.0 | 2.2 | 42 | 4,120 | 2,210 | 500 |
400 | 3.0 | 1.3 | 2.5 | 2.4 | 47 | 5,250 | 2,820 | 500 |
500 | 3.2 | 1.3 | 2.5 | 2.5 | 51 | 6,450 | 3,340 | 500 |
630 | 3.2 | 1.4 | 2.5 | 2.6 | 55 | 7,990 | 3,950 | 400 |
Three-core,CU/XLPE/SWA/PVC or AL/XLPE/SWA/PVC (Table 22)
Conductor Nominal Area | Insulation Thickness | Approx. Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.2 | 2.0 | 2.1 | 40 | 2,310 | 2,120 | 500 |
16 | 2.5 | 1.2 | 2.0 | 2.2 | 42 | 2,600 | 2,290 | 500 |
25 | 2.5 | 1.2 | 2.0 | 2.3 | 45 | 3,080 | 2,600 | 500 |
35 | 2.5 | 1.3 | 2.5 | 2.4 | 48 | 3,950 | 3,280 | 500 |
50 | 2.5 | 1.3 | 2.5 | 2.5 | 54 | 4,530 | 3,630 | 500 |
70 | 2.5 | 1.4 | 2.5 | 2.6 | 55 | 5,510 | 4,210 | 500 |
95 | 2.5 | 1.5 | 2.5 | 2.8 | 59 | 6,660 | 4,860 | 500 |
120 | 2.5 | 1.5 | 2.5 | 2.9 | 63 | 7,630 | 5,360 | 400 |
150 | 2.5 | 1.6 | 2.5 | 3.0 | 66 | 8,800 | 6,000 | 400 |
185 | 2.5 | 1.7 | 3.15 | 3.2 | 72 | 11,500 | 6,670 | 300 |
240 | 2.6 | 1.8 | 3.15 | 3.4 | 78 | 13,480 | 8,870 | 250 |
300 | 2.8 | 1.9 | 3.15 | 3.6 | 84 | 15,920 | 10,130 | 200 |
400 | 3.0 | 2.0 | 4.0 | 3.9 | 94 | 21,300 | 12,590 | 200 |
500 | 3.2 | 2.1 | 4.0 | 4.1 | 103 | 25,090 | 15,610 | 200 |
3.6/6(7.2)kV,XLPE Insulated Tape Armored PVC Sheathed Power Cable
Single-core,CU/XLPE/ATA/PVCor AL/XLPE/ATA/PVC (Table 23)
Conductor Nominal Area | Insulation Thickness | Approx. Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.2 | 0.5 | 1.8 | 22 | 530 | 460 | 500 |
16 | 2.5 | 1.2 | 0.5 | 1.8 | 23 | 600 | 500 | 500 |
25 | 2.5 | 1.2 | 0.5 | 1.8 | 24 | 730 | 570 | 500 |
35 | 2.5 | 1.2 | 0.5 | 1.8 | 25 | 850 | 630 | 500 |
50 | 2.5 | 1.2 | 0.5 | 1.8 | 26 | 1,000 | 700 | 500 |
70 | 2.5 | 1.2 | 0.5 | 1.8 | 28 | 1,240 | 820 | 500 |
95 | 2.5 | 1.2 | 0.5 | 1.8 | 30 | 1,540 | 950 | 500 |
120 | 2.5 | 1.2 | 0.5 | 1.8 | 31 | 1,820 | 1,080 | 500 |
150 | 2.5 | 1.2 | 0.5 | 1.9 | 33 | 2,120 | 1,200 | 500 |
185 | 2.5 | 1.2 | 0.5 | 1.9 | 35 | 2,520 | 1,370 | 500 |
240 | 2.6 | 1.2 | 0.5 | 2.0 | 37 | 3,180 | 1,670 | 500 |
300 | 2.8 | 1.2 | 0.5 | 2.1 | 40 | 3,850 | 1,950 | 500 |
400 | 3.0 | 1.3 | 0.5 | 2.3 | 44 | 4,800 | 2,370 | 500 |
500 | 3.2 | 1.3 | 0.5 | 2.4 | 48 | 5,960 | 2,840 | 500 |
630 | 3.2 | 1.4 | 0.5 | 2.5 | 52 | 7,450 | 3,410 | 600 |
Three-core,CU/XLPE/STA/PVCor AL/XLPE/STA/PVC (Table 24)
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.2 | 0.2 | 2.0 | 37 | 1,330 | 1,140 | 500 |
16 | 2.5 | 1.2 | 0.5 | 2.1 | 40 | 1,580 | 1,580 | 500 |
25 | 2.5 | 1.2 | 0.5 | 2.2 | 42 | 2,310 | 1,880 | 500 |
35 | 2.5 | 1.3 | 0.5 | 2.3 | 45 | 2,760 | 2,090 | 500 |
50 | 2.5 | 1.3 | 0.5 | 2.4 | 48 | 3,260 | 2,360 | 500 |
70 | 2.5 | 1.4 | 0.5 | 2.5 | 52 | 4,100 | 2,810 | 500 |
95 | 2.5 | 1.5 | 0.5 | 2.7 | 56 | 5,110 | 3,310 | 500 |
120 | 2.5 | 1.5 | 0.5 | 2.8 | 60 | 5,010 | 3,750 | 400 |
150 | 2.5 | 1.6 | 0.5 | 2.9 | 63 | 7,050 | 4,250 | 400 |
185 | 2.5 | 1.7 | 0.5 | 3.0 | 67 | 9,320 | 4,820 | 400 |
240 | 2.6 | 1.8 | 0.5 | 3.2 | 73 | 10,530 | 5,920 | 300 |
300 | 2.8 | 1.9 | 0.5 | 3.4 | 79 | 12,730 | 6,940 | 300 |
400 | 3.0 | 2.0 | 0.8 | 3.7 | 89 | 16,620 | 9,240 | 200 |
500 | 3.2 | 2.1 | 0.8 | 4.0 | 98 | 20,550 | 11,070 | 200 |
Copper Conductor:
High conductivity for efficient power transmission.
Excellent mechanical strength and durability.
Suitable for heavy-duty applications.
XLPE Insulation (Cross-Linked Polyethylene):
Provides excellent thermal and electrical properties.
High resistance to heat, chemicals, and moisture.
Operates efficiently at higher temperatures compared to PVC insulation.
Steel Wire Armouring:
Offers superior mechanical protection against external stresses, such as impact, crushing, and abrasion.
Enhances the cable's durability in harsh environments, including underground or industrial settings.
Voltage Rating:
Designed for medium-voltage applications up to 6kV.
Heavy-Duty Construction:
Built to withstand extreme conditions, making it ideal for industrial, mining, and outdoor installations.
Compliance:
Meets international standards such as IEC, BS, or ASTM, ensuring safety and reliability.
Industrial Plants: Suitable for power distribution in factories, refineries, and chemical plants.
Mining Operations: Ideal for rugged environments with high mechanical stress.
Underground Installations: Protected against moisture and physical damage.
Renewable Energy Projects: Used in wind farms and solar power plants for reliable power transmission.
Infrastructure Projects: Suitable for power grids, tunnels, and construction sites.
High Durability: Steel wire armouring ensures long-term performance in tough conditions.
Efficient Power Transmission: Copper conductor and XLPE insulation minimize energy losses.
Safety: XLPE insulation provides excellent resistance to short circuits and electrical faults.
Flexibility: Can be used in fixed installations or where mechanical stress is a concern.
Voltage Rating: 6kV (6000 volts)
Conductor Material: Copper (Class 2 stranded)
Insulation Material: XLPE (Cross-Linked Polyethylene)
Armouring: Steel Wire Armour (SWA)
Sheath: PVC or LSZH (Low Smoke Zero Halogen) for additional protection
Temperature Range: -20°C to +90°C (operating)
Standards: IEC 60502, BS 5467, or equivalent
Standard Packaging: Wooden reels or coils (100m–5000m lengths).
- Protection: Moisture-proof wrapping, shock-absorbent pallets.
- Labeling: Clear voltage ratings, certifications, and batch codes.
- Shipping Compliance: IEC 60228 for mechanical protection during transit.
Heavy-Duty 6kV Power Cable with Copper Conductor and XLPE Insulation, Protected by Steel Wire Armouring is a robust and reliable solution for transmitting electrical power in demanding environments.
The Heavy-Duty 6kV Power Cable with Copper Conductor, XLPE Insulation, and Steel Wire Armouring typically complies with international and regional standards to ensure safety, reliability, and performance. Below are some of the key standards that such cables often adhere to:
IEC (International Electrotechnical Commission):
IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1.2 kV) up to 30 kV (Um = 36 kV).
IEC 60228: Conductors of insulated cables (specifies conductor classes and requirements).
IEC 60332: Tests for vertical flame propagation for insulated cables.
IEC 60754: Test on gases evolved during combustion of materials from cables.
ISO (International Organization for Standardization):
ISO 9001: Quality management systems (for manufacturing processes).
3.6/6(7.2)kV,XLPE Insulated Unarmored PVC Sheathed Power Cable
Single-core,CU/XLPE/PVC or AL/XLPE/PVC (Table 19)
Conductor Nominal Area | Insulation Thickness | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||
mm² | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.8 | 15 | 320 | 260 | 500 |
16 | 2.5 | 1.8 | 18 | 390 | 290 | 500 |
25 | 2.5 | 1.8 | 20 | 500 | 340 | 500 |
35 | 2.5 | 1.8 | 21 | 610 | 400 | 500 |
50 | 2.5 | 1.8 | 22 | 750 | 450 | 500 |
70 | 2.5 | 1.8 | 24 | 970 | 550 | 500 |
95 | 2.5 | 1.8 | 25 | 1,250 | 660 | 500 |
120 | 2.5 | 1.8 | 27 | 1,500 | 760 | 500 |
150 | 2.5 | 1.8 | 28 | 1,790 | 860 | 500 |
185 | 2.5 | 1.9 | 30 | 2,150 | 1,000 | 500 |
240 | 2.6 | 1.9 | 33 | 2,770 | 1,250 | 500 |
300 | 2.8 | 2.0 | 35 | 3,400 | 1,500 | 500 |
400 | 3.0 | 2.1 | 39 | 4,280 | 1.850 | 500 |
500 | 3.2 | 2.2 | 43 | 5,400 | 2,280 | 500 |
630 | 3.2 | 2.4 | 47 | 6,830 | 2,800 | 500 |
800 | 3.2 | 2.5 | 51 | 8,570 | 3,400 | 400 |
1,000 | 3.2 | 2.6 | 56 | 10,590 | 4,110 | 300 |
Three-core,CU/XLPE/PVC or AL/XLPE/PVC (Table 20)
Conductor Nominal Area | Insulation Thickness | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||
mm² | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.9 | 33 | 980 | 790 | 500 |
16 | 2.5 | 2.0 | 35 | 1,190 | 890 | 500 |
25 | 2.5 | 2.1 | 38 | 1,560 | 1,080 | 500 |
35 | 2.5 | 2.2 | 40 | 1,930 | 1,270 | 500 |
50 | 2.5 | 2.3 | 43 | 2,370 | 1,480 | 500 |
70 | 2.5 | 2.4 | 47 | 3,110 | 1,820 | 500 |
95 | 2.5 | 2.5 | 51 | 4,000 | 2,200 | 500 |
120 | 2.5 | 2.6 | 54 | 4,820 | 2,550 | 500 |
150 | 2.5 | 2.7 | 58 | 5,770 | 2,970 | 500 |
185 | 2.5 | 2.8 | 61 | 6,960 | 3,460 | 500 |
240 | 2.6 | 3.0 | 68 | 8,940 | 4,340 | 400 |
300 | 2.8 | 3.2 | 73 | 10,980 | 5,190 | 300 |
400 | 3.0 | 3.5 | 81 | 13,820 | 6,440 | 250 |
500 | 3.2 | 3.7 | 90 | 17,390 | 7,910 | 200 |
3.6/6(7.2)kV,XLPE Insulated Wire Armored PVC Sheathed Power Cable
Single-core,CU/XLPE/AWA/PVC orAL/XLPE/AWA/PVC (Table 21)
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.2 | 0.9 | 1.8 | 22 | 610 | 550 | 500 |
16 | 2.5 | 1.2 | 1.6 | 1.8 | 24 | 680 | 580 | 500 |
25 | 2.5 | 1.2 | 1.6 | 1.8 | 25 | 810 | 660 | 500 |
35 | 2.5 | 1.2 | 1.6 | 1.8 | 26 | 940 | 730 | 500 |
50 | 2.5 | 1.2 | 1.6 | 1.8 | 27 | 1,100 | 810 | 500 |
70 | 2.5 | 1.2 | 1.6 | 1.8 | 29 | 1,350 | 930 | 500 |
95 | 2.5 | 1.2 | 1.6 | 1.9 | 31 | 1,670 | 1,080 | 500 |
120 | 2.5 | 1.2 | 1.6 | 1.9 | 32 | 1,950 | 1,200 | 500 |
150 | 2.5 | 1.2 | 1.6 | 2.0 | 34 | 2,270 | 1,350 | 500 |
185 | 2.5 | 1.2 | 2.0 | 2.1 | 37 | 2,770 | 1,620 | 500 |
240 | 2.6 | 1.2 | 2.0 | 2.2 | 40 | 3,440 | 1,930 | 500 |
300 | 2.8 | 1.2 | 2.0 | 2.2 | 42 | 4,120 | 2,210 | 500 |
400 | 3.0 | 1.3 | 2.5 | 2.4 | 47 | 5,250 | 2,820 | 500 |
500 | 3.2 | 1.3 | 2.5 | 2.5 | 51 | 6,450 | 3,340 | 500 |
630 | 3.2 | 1.4 | 2.5 | 2.6 | 55 | 7,990 | 3,950 | 400 |
Three-core,CU/XLPE/SWA/PVC or AL/XLPE/SWA/PVC (Table 22)
Conductor Nominal Area | Insulation Thickness | Approx. Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.2 | 2.0 | 2.1 | 40 | 2,310 | 2,120 | 500 |
16 | 2.5 | 1.2 | 2.0 | 2.2 | 42 | 2,600 | 2,290 | 500 |
25 | 2.5 | 1.2 | 2.0 | 2.3 | 45 | 3,080 | 2,600 | 500 |
35 | 2.5 | 1.3 | 2.5 | 2.4 | 48 | 3,950 | 3,280 | 500 |
50 | 2.5 | 1.3 | 2.5 | 2.5 | 54 | 4,530 | 3,630 | 500 |
70 | 2.5 | 1.4 | 2.5 | 2.6 | 55 | 5,510 | 4,210 | 500 |
95 | 2.5 | 1.5 | 2.5 | 2.8 | 59 | 6,660 | 4,860 | 500 |
120 | 2.5 | 1.5 | 2.5 | 2.9 | 63 | 7,630 | 5,360 | 400 |
150 | 2.5 | 1.6 | 2.5 | 3.0 | 66 | 8,800 | 6,000 | 400 |
185 | 2.5 | 1.7 | 3.15 | 3.2 | 72 | 11,500 | 6,670 | 300 |
240 | 2.6 | 1.8 | 3.15 | 3.4 | 78 | 13,480 | 8,870 | 250 |
300 | 2.8 | 1.9 | 3.15 | 3.6 | 84 | 15,920 | 10,130 | 200 |
400 | 3.0 | 2.0 | 4.0 | 3.9 | 94 | 21,300 | 12,590 | 200 |
500 | 3.2 | 2.1 | 4.0 | 4.1 | 103 | 25,090 | 15,610 | 200 |
3.6/6(7.2)kV,XLPE Insulated Tape Armored PVC Sheathed Power Cable
Single-core,CU/XLPE/ATA/PVCor AL/XLPE/ATA/PVC (Table 23)
Conductor Nominal Area | Insulation Thickness | Approx. Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.2 | 0.5 | 1.8 | 22 | 530 | 460 | 500 |
16 | 2.5 | 1.2 | 0.5 | 1.8 | 23 | 600 | 500 | 500 |
25 | 2.5 | 1.2 | 0.5 | 1.8 | 24 | 730 | 570 | 500 |
35 | 2.5 | 1.2 | 0.5 | 1.8 | 25 | 850 | 630 | 500 |
50 | 2.5 | 1.2 | 0.5 | 1.8 | 26 | 1,000 | 700 | 500 |
70 | 2.5 | 1.2 | 0.5 | 1.8 | 28 | 1,240 | 820 | 500 |
95 | 2.5 | 1.2 | 0.5 | 1.8 | 30 | 1,540 | 950 | 500 |
120 | 2.5 | 1.2 | 0.5 | 1.8 | 31 | 1,820 | 1,080 | 500 |
150 | 2.5 | 1.2 | 0.5 | 1.9 | 33 | 2,120 | 1,200 | 500 |
185 | 2.5 | 1.2 | 0.5 | 1.9 | 35 | 2,520 | 1,370 | 500 |
240 | 2.6 | 1.2 | 0.5 | 2.0 | 37 | 3,180 | 1,670 | 500 |
300 | 2.8 | 1.2 | 0.5 | 2.1 | 40 | 3,850 | 1,950 | 500 |
400 | 3.0 | 1.3 | 0.5 | 2.3 | 44 | 4,800 | 2,370 | 500 |
500 | 3.2 | 1.3 | 0.5 | 2.4 | 48 | 5,960 | 2,840 | 500 |
630 | 3.2 | 1.4 | 0.5 | 2.5 | 52 | 7,450 | 3,410 | 600 |
Three-core,CU/XLPE/STA/PVCor AL/XLPE/STA/PVC (Table 24)
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
10 | 2.5 | 1.2 | 0.2 | 2.0 | 37 | 1,330 | 1,140 | 500 |
16 | 2.5 | 1.2 | 0.5 | 2.1 | 40 | 1,580 | 1,580 | 500 |
25 | 2.5 | 1.2 | 0.5 | 2.2 | 42 | 2,310 | 1,880 | 500 |
35 | 2.5 | 1.3 | 0.5 | 2.3 | 45 | 2,760 | 2,090 | 500 |
50 | 2.5 | 1.3 | 0.5 | 2.4 | 48 | 3,260 | 2,360 | 500 |
70 | 2.5 | 1.4 | 0.5 | 2.5 | 52 | 4,100 | 2,810 | 500 |
95 | 2.5 | 1.5 | 0.5 | 2.7 | 56 | 5,110 | 3,310 | 500 |
120 | 2.5 | 1.5 | 0.5 | 2.8 | 60 | 5,010 | 3,750 | 400 |
150 | 2.5 | 1.6 | 0.5 | 2.9 | 63 | 7,050 | 4,250 | 400 |
185 | 2.5 | 1.7 | 0.5 | 3.0 | 67 | 9,320 | 4,820 | 400 |
240 | 2.6 | 1.8 | 0.5 | 3.2 | 73 | 10,530 | 5,920 | 300 |
300 | 2.8 | 1.9 | 0.5 | 3.4 | 79 | 12,730 | 6,940 | 300 |
400 | 3.0 | 2.0 | 0.8 | 3.7 | 89 | 16,620 | 9,240 | 200 |
500 | 3.2 | 2.1 | 0.8 | 4.0 | 98 | 20,550 | 11,070 | 200 |
Copper Conductor:
High conductivity for efficient power transmission.
Excellent mechanical strength and durability.
Suitable for heavy-duty applications.
XLPE Insulation (Cross-Linked Polyethylene):
Provides excellent thermal and electrical properties.
High resistance to heat, chemicals, and moisture.
Operates efficiently at higher temperatures compared to PVC insulation.
Steel Wire Armouring:
Offers superior mechanical protection against external stresses, such as impact, crushing, and abrasion.
Enhances the cable's durability in harsh environments, including underground or industrial settings.
Voltage Rating:
Designed for medium-voltage applications up to 6kV.
Heavy-Duty Construction:
Built to withstand extreme conditions, making it ideal for industrial, mining, and outdoor installations.
Compliance:
Meets international standards such as IEC, BS, or ASTM, ensuring safety and reliability.
Industrial Plants: Suitable for power distribution in factories, refineries, and chemical plants.
Mining Operations: Ideal for rugged environments with high mechanical stress.
Underground Installations: Protected against moisture and physical damage.
Renewable Energy Projects: Used in wind farms and solar power plants for reliable power transmission.
Infrastructure Projects: Suitable for power grids, tunnels, and construction sites.
High Durability: Steel wire armouring ensures long-term performance in tough conditions.
Efficient Power Transmission: Copper conductor and XLPE insulation minimize energy losses.
Safety: XLPE insulation provides excellent resistance to short circuits and electrical faults.
Flexibility: Can be used in fixed installations or where mechanical stress is a concern.
Voltage Rating: 6kV (6000 volts)
Conductor Material: Copper (Class 2 stranded)
Insulation Material: XLPE (Cross-Linked Polyethylene)
Armouring: Steel Wire Armour (SWA)
Sheath: PVC or LSZH (Low Smoke Zero Halogen) for additional protection
Temperature Range: -20°C to +90°C (operating)
Standards: IEC 60502, BS 5467, or equivalent
Standard Packaging: Wooden reels or coils (100m–5000m lengths).
- Protection: Moisture-proof wrapping, shock-absorbent pallets.
- Labeling: Clear voltage ratings, certifications, and batch codes.
- Shipping Compliance: IEC 60228 for mechanical protection during transit.