cross sectional area: | |
---|---|
Availability: | |
Quantity: | |
YJV
8544601290
Product Description
Applications
- Power Distribution Networks: Substations, transformers, and switchgear.
- Industrial Plants: Mining, oil & gas, and manufacturing facilities.
- Renewable Energy: Wind farms, solar parks, and hydropower stations.
-Infrastructure:Underground metro systems, airports, and hospitals.
Features
- High Efficiency: Low dielectric losses for reduced energy waste.
- Durability: Resistant to moisture, chemicals, UV radiation, and abrasion.
- Safety: Flame-retardant and low-smoke materials for confined spaces.
- Flexibility: Armored/non-armored options for diverse installation needs.
- Long Lifespan: >30 years under standard operating conditions.
Standards
MV power cables comply with globally recognized standards to ensure safety and compatibility:
- International Electrotechnical Commission (IEC): IEC 60502, IEC 60228
- Institute of Electrical and Electronics Engineers (IEEE): IEEE 386, IEEE 575
- Association of Edison Illuminating Companies (AEIC): AEIC CS8
- National Electrical Manufacturers Association (NEMA): NEMA WC 74
Construction
MV cables feature a robust layered design for optimal performance:
1. Conductor: High-purity copper or aluminum (stranded/solid) per IEC 60228.
2. Conductor Screen: Semiconducting layer to minimize electric field stress.
3. Insulation: Cross-linked polyethylene (XLPE) or ethylene propylene rubber (EPR) for thermal stability.
4. Insulation Screen: Semiconducting layer to ensure uniform voltage distribution.
5. Metallic Shield: Copper wire/tape or aluminum armor for grounding and fault protection.
6. Outer Sheath: PVC, LSZH (Low Smoke Zero Halogen), or HDPE for mechanical and environmental protection.
Key Parameters
- Voltage Rating: 1 kV to 36 kV (U0/U: 0.6/1 kV to 26/36 kV).
- Temperature Range:
- Normal Operation: -40°C to +90°C (XLPE), -50°C to +105°C (EPR).
- Short-Circuit: Up to +250°C (XLPE), +250°C (EPR).
- Current Carrying Capacity: Varies with conductor size (e.g., 240 mm² to 1000 mm²).
- Bending Radius: 12–20× cable diameter (depends on construction).
Technical Data
Property | Specification |
Insulation Resistance | >1000 MΩ·km at 20°C |
Dielectric Strength | 3.5–30 kV/mm (depending on voltage grade) |
Fire Resistance | IEC 60332 (flame retardant), IEC 61034 (low smoke) |
Crush Resistance | >10 kN/m (tested per IEC 60229) |
6/6kV, 6/10(12)kV, XLPE Insulated Unarmored PVC Sheathed Power Cable
Single-core, CU/XLPE/PVC or AL/XLPE/PVC
Conductor Nominal Area | Insulation Thickness | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||
mm² | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.8 | 20 | 450 | 350 | 500 |
25 | 3.4 | 1.8 | 21 | 560 | 400 | 500 |
35 | 3.4 | 1.8 | 22 | 680 | 460 | 500 |
50 | 3.4 | 1.8 | 24 | 810 | 520 | 500 |
70 | 3.4 | 1.8 | 25 | 1,050 | 620 | 500 |
95 | 3.4 | 1.8 | 27 | 1,320 | 730 | 500 |
120 | 3.4 | 1.8 | 28 | 1,580 | 840 | 500 |
150 | 3.4 | 1.9 | 30 | 1,880 | 960 | 500 |
185 | 3.4 | 1.9 | 32 | 2,250 | 1,100 | 500 |
240 | 3.4 | 2.0 | 34 | 2,870 | 1,350 | 500 |
300 | 3.4 | 2.1 | 37 | 3,490 | 1,580 | 500 |
400 | 3.4 | 2.2 | 40 | 4,350 | 1,920 | 500 |
500 | 3.4 | 2.3 | 44 | 5,440 | 2,320 | 500 |
630 | 3.4 | 2.4 | 48 | 6,860 | 2,830 | 500 |
800 | 3.4 | 2.5 | 52 | 8,600 | 3,430 | 400 |
1.000 | 3.4 | 2.6 | 56 | 10,630 | 4,150 | 300 |
Three-core,CU/XLPE/PVC or AL/XLPE/PVC
Conductor Nominal Area | Insulation Thickness | Outer Sheath Thickness | Approx. Overall Diameter | Approx.Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||
mm² | mm | mm | mm | kg/km | m | |
16 | 3.4 | 2.1 | 39 | 1,410 | 1,110 | 500 |
25 | 3.4 | 2.2 | 42 | 1,800 | 1,320 | 500 |
35 | 3.4 | 2.3 | 45 | 2,170 | 1,500 | 500 |
50 | 3.4 | 2.4 | 47 | 2,630 | 1,730 | 500 |
70 | 3.4 | 2.5 | 51 | 3,400 | 2,110 | 500 |
95 | 3.4 | 2.6 | 55 | 4,310 | 2,510 | 500 |
120 | 3.4 | 2.7 | 58 | 5,150 | 2,860 | 500 |
150 | 3.4 | 2.9 | 62 | 6,100 | 3,300 | 500 |
185 | 3.4 | 3.0 | 66 | 7,310 | 3,810 | 500 |
240 | 3.4 | 3.1 | 71 | 9,290 | 4,680 | 400 |
300 | 3.4 | 3.3 | 76 | 11,240 | 5,450 | 300 |
400 | 3.4 | 3.5 | 83 | 14,040 | 6,660 | 250 |
500 | 3.4 | 3.7 | 91 | 17,530 | 8,050 | 200 |
6/6kV,6/10(12)kV,XLPE Insulated Wire Armored PVC Sheathed Power Cable
Single-core,CU/XLPE/AWA/PVC or AL/XLPE/AWA/PVC
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.2 | 1.6 | 1.8 | 26 | 770 | 670 | 500 |
25 | 3.4 | 1.2 | 1.6 | 1.8 | 27 | 910 | 750 | 500 |
35 | 3.4 | 1.2 | 1.6 | 1.8 | 28 | 1,040 | 820 | 500 |
50 | 3.4 | 1.2 | 1.6 | 1.8 | 29 | 1,190 | 900 | 500 |
70 | 3.4 | 1.2 | 1.6 | 1.9 | 31 | 1,470 | 1,040 | 500 |
95 | 3.4 | 1.2 | 1.6 | 2.0 | 33 | 1,780 | 1,190 | 500 |
120 | 3.4 | 1.2 | 2.0 | 2.0 | 35 | 2,150 | 1,410 | 500 |
150 | 3.4 | 1.2 | 2.0 | 2.1 | 37 | 2,480 | 1,560 | 500 |
185 | 3.4 | 1.2 | 2.0 | 2.1 | 39 | 2,890 | 1,730 | 500 |
240 | 3.4 | 1.2 | 2.0 | 2.2 | 41 | 3,570 | 2,050 | 500 |
300 | 3.4 | 1.2 | 2.0 | 2.3 | 44 | 4,230 | 2,330 | 500 |
400 | 3.4 | 1.3 | 2.5 | 2.4 | 48 | 5,320 | 2,890 | 500 |
500 | 3.4 | 1.3 | 2.5 | 2.5 | 52 | 6,500 | 3,380 | 500 |
630 | 3.4 | 1.4 | 2.5 | 2.6 | 56 | 8,020 | 3,990 | 400 |
Three-core,CU/XLPE/SWA/PVC or AL/XLPE/SWA/PVC
Conductor Nominal Area | Insulation Thickness | Approx. Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.3 | 2.5 | 2.4 | 47 | 3,700 | 2,700 | 500 |
25 | 3.4 | 1.3 | 2.5 | 2.5 | 50 | 3,900 | 3,430 | 500 |
35 | 3.4 | 1.3 | 2.5 | 2.6 | 53 | 4,430 | 3,770 | 500 |
50 | 3.4 | 1.4 | 2.5 | 2.7 | 56 | 5,080 | 4,190 | 500 |
70 | 3.4 | 1.5 | 2.5 | 2.8 | 60 | 6,050 | 4,750 | 500 |
95 | 3.4 | 1.5 | 2.5 | 2.9 | 64 | 7,180 | 5,380 | 500 |
120 | 3.4 | 1.6 | 2.5 | 3.0 | 67 | 8,230 | 5,960 | 400 |
150 | 3.4 | 1.7 | 3.15 | 3.2 | 72 | 10,100 | 6,580 | 300 |
185 | 3.4 | 1.7 | 3.15 | 3.3 | 76 | 11,610 | 8,110 | 300 |
240 | 3.4 | 1.8 | 3.15 | 3.5 | 82 | 14,110 | 9,510 | 250 |
300 | 3.4 | 1.9 | 3.15 | 3.7 | 87 | 16,420 | 10,630 | 200 |
400 | 3.4 | 2.0 | 4.0 | 4.0 | 96 | 21,700 | 12,880 | 200 |
500 | 3.4 | 2.2 | 4.0 | 4.2 | 104 | 25,280 | 15,800 | 200 |
6/6kV,6/10(12)kV,XLPE Insulated Tape Armored PVC Sheathed Power Cable
Single-core,CU/XLPE/ATA/PVC or AL/XLPE/ATA/PVC
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.2 | 0.5 | 1.8 | 25 | 680 | 580 | 500 |
25 | 3.4 | 1.2 | 0.5 | 1.8 | 26 | 810 | 650 | 500 |
35 | 3.4 | 1.2 | 0.5 | 1.8 | 27 | 940 | 720 | 500 |
50 | 3.4 | 1.2 | 0.5 | 1.8 | 28 | 1,090 | 790 | 500 |
70 | 3.4 | 1.2 | 0.5 | 1.9 | 30 | 1,350 | 920 | 500 |
95 | 3.4 | 1.2 | 0.5 | 1.9 | 32 | 1,650 | 1,060 | 500 |
120 | 3.4 | 1.2 | 0.5 | 2.0 | 33 | 1,940 | 1,190 | 500 |
150 | 3.4 | 1.2 | 0.5 | 2.0 | 35 | 2,240 | 1,320 | 500 |
185 | 3.4 | 1.2 | 0.5 | 2.1 | 37 | 2,650 | 1,500 | 500 |
240 | 3.4 | 1.2 | 0.5 | 2.1 | 39 | 3,290 | 1,770 | 500 |
300 | 3.4 | 1.2 | 0.5 | 2.2 | 41 | 3,940 | 2,030 | 500 |
400 | 3.4 | 1.3 | 0.5 | 2.3 | 45 | 4,860 | 2,430 | 500 |
500 | 3.4 | 1.3 | 0.5 | 2.4 | 49 | 5,990 | 2,880 | 500 |
630 | 3.4 | 1.4 | 0.5 | 2.5 | 52 | 7,480 | 3,450 | 500 |
Three-core,CU/XLPE/STA/PVC or AL/XLPE/STA/PVC
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.3 | 0.2 | 2.3 | 44 | 2,220 | 1,900 | 500 |
25 | 3.4 | 1.3 | 0.5 | 2.4 | 47 | 2,660 | 2,180 | 500 |
35 | 3.4 | 1.3 | 0.5 | 2.5 | 50 | 3,110 | 2,440 | 500 |
50 | 3.4 | 1.4 | 0.5 | 2.6 | 53 | 3,650 | 2,750 | 500 |
70 | 3.4 | 1.5 | 0.5 | 2.7 | 56 | 4,510 | 3,220 | 500 |
95 | 3.4 | 1.5 | 0.5 | 2.8 | 60 | 5,510 | 3,710 | 500 |
120 | 3.4 | 1.6 | 0.5 | 2.9 | 64 | 6,450 | 4,180 | 500 |
150 | 3.4 | 1.7 | 0.5 | 3.1 | 68 | 7,500 | 4,700 | 400 |
185 | 3.4 | 1.7 | 0.5 | 3.2 | 71 | 8,830 | 5,330 | 400 |
240 | 3.4 | 1.8 | 0.5 | 3.3 | 77 | 10,960 | 6,360 | 300 |
300 | 3.4 | 1.9 | 0.5 | 3.5 | 82 | 13,090 | 7,300 | 250 |
400 | 3.4 | 2.0 | 0.8 | 3.8 | 91 | 16,910 | 9,530 | 200 |
500 | 3.4 | 2.2 | 0.8 | 4.0 | 99 | 20,720 | 11,250 | 200 |
Packing & Shipping
- Packaging: Wooden drums or steel-reinforced reels with waterproof wrapping.
- Labeling: IEC-compliant markings (voltage, size, manufacturing date).
- Shipping: ISO-compliant containers with shockproof securing.
- Storage: Dry, ventilated environments; avoid direct sunlight.
Why choose us?
1. Export to many countries including Iraq, Tanzania and Australia and USA.
2. Best manufacturing and testing equipments imported from Germany, USA and Japan guarantee the best quality with competitive prices.
3. Professional overseas team guarantees you best pre-and-after sale services.
4. Experienced engineers and workers for more than 20 years ensure the quality and customized products.
5. 5S Management to enhance the qualifications of staff and make better service for customers.
6. Near Shanghai and Ningbo Port workshop makes it convenient to delivery on time.
Product Description
Applications
- Power Distribution Networks: Substations, transformers, and switchgear.
- Industrial Plants: Mining, oil & gas, and manufacturing facilities.
- Renewable Energy: Wind farms, solar parks, and hydropower stations.
-Infrastructure:Underground metro systems, airports, and hospitals.
Features
- High Efficiency: Low dielectric losses for reduced energy waste.
- Durability: Resistant to moisture, chemicals, UV radiation, and abrasion.
- Safety: Flame-retardant and low-smoke materials for confined spaces.
- Flexibility: Armored/non-armored options for diverse installation needs.
- Long Lifespan: >30 years under standard operating conditions.
Standards
MV power cables comply with globally recognized standards to ensure safety and compatibility:
- International Electrotechnical Commission (IEC): IEC 60502, IEC 60228
- Institute of Electrical and Electronics Engineers (IEEE): IEEE 386, IEEE 575
- Association of Edison Illuminating Companies (AEIC): AEIC CS8
- National Electrical Manufacturers Association (NEMA): NEMA WC 74
Construction
MV cables feature a robust layered design for optimal performance:
1. Conductor: High-purity copper or aluminum (stranded/solid) per IEC 60228.
2. Conductor Screen: Semiconducting layer to minimize electric field stress.
3. Insulation: Cross-linked polyethylene (XLPE) or ethylene propylene rubber (EPR) for thermal stability.
4. Insulation Screen: Semiconducting layer to ensure uniform voltage distribution.
5. Metallic Shield: Copper wire/tape or aluminum armor for grounding and fault protection.
6. Outer Sheath: PVC, LSZH (Low Smoke Zero Halogen), or HDPE for mechanical and environmental protection.
Key Parameters
- Voltage Rating: 1 kV to 36 kV (U0/U: 0.6/1 kV to 26/36 kV).
- Temperature Range:
- Normal Operation: -40°C to +90°C (XLPE), -50°C to +105°C (EPR).
- Short-Circuit: Up to +250°C (XLPE), +250°C (EPR).
- Current Carrying Capacity: Varies with conductor size (e.g., 240 mm² to 1000 mm²).
- Bending Radius: 12–20× cable diameter (depends on construction).
Technical Data
Property | Specification |
Insulation Resistance | >1000 MΩ·km at 20°C |
Dielectric Strength | 3.5–30 kV/mm (depending on voltage grade) |
Fire Resistance | IEC 60332 (flame retardant), IEC 61034 (low smoke) |
Crush Resistance | >10 kN/m (tested per IEC 60229) |
6/6kV, 6/10(12)kV, XLPE Insulated Unarmored PVC Sheathed Power Cable
Single-core, CU/XLPE/PVC or AL/XLPE/PVC
Conductor Nominal Area | Insulation Thickness | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||
mm² | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.8 | 20 | 450 | 350 | 500 |
25 | 3.4 | 1.8 | 21 | 560 | 400 | 500 |
35 | 3.4 | 1.8 | 22 | 680 | 460 | 500 |
50 | 3.4 | 1.8 | 24 | 810 | 520 | 500 |
70 | 3.4 | 1.8 | 25 | 1,050 | 620 | 500 |
95 | 3.4 | 1.8 | 27 | 1,320 | 730 | 500 |
120 | 3.4 | 1.8 | 28 | 1,580 | 840 | 500 |
150 | 3.4 | 1.9 | 30 | 1,880 | 960 | 500 |
185 | 3.4 | 1.9 | 32 | 2,250 | 1,100 | 500 |
240 | 3.4 | 2.0 | 34 | 2,870 | 1,350 | 500 |
300 | 3.4 | 2.1 | 37 | 3,490 | 1,580 | 500 |
400 | 3.4 | 2.2 | 40 | 4,350 | 1,920 | 500 |
500 | 3.4 | 2.3 | 44 | 5,440 | 2,320 | 500 |
630 | 3.4 | 2.4 | 48 | 6,860 | 2,830 | 500 |
800 | 3.4 | 2.5 | 52 | 8,600 | 3,430 | 400 |
1.000 | 3.4 | 2.6 | 56 | 10,630 | 4,150 | 300 |
Three-core,CU/XLPE/PVC or AL/XLPE/PVC
Conductor Nominal Area | Insulation Thickness | Outer Sheath Thickness | Approx. Overall Diameter | Approx.Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||
mm² | mm | mm | mm | kg/km | m | |
16 | 3.4 | 2.1 | 39 | 1,410 | 1,110 | 500 |
25 | 3.4 | 2.2 | 42 | 1,800 | 1,320 | 500 |
35 | 3.4 | 2.3 | 45 | 2,170 | 1,500 | 500 |
50 | 3.4 | 2.4 | 47 | 2,630 | 1,730 | 500 |
70 | 3.4 | 2.5 | 51 | 3,400 | 2,110 | 500 |
95 | 3.4 | 2.6 | 55 | 4,310 | 2,510 | 500 |
120 | 3.4 | 2.7 | 58 | 5,150 | 2,860 | 500 |
150 | 3.4 | 2.9 | 62 | 6,100 | 3,300 | 500 |
185 | 3.4 | 3.0 | 66 | 7,310 | 3,810 | 500 |
240 | 3.4 | 3.1 | 71 | 9,290 | 4,680 | 400 |
300 | 3.4 | 3.3 | 76 | 11,240 | 5,450 | 300 |
400 | 3.4 | 3.5 | 83 | 14,040 | 6,660 | 250 |
500 | 3.4 | 3.7 | 91 | 17,530 | 8,050 | 200 |
6/6kV,6/10(12)kV,XLPE Insulated Wire Armored PVC Sheathed Power Cable
Single-core,CU/XLPE/AWA/PVC or AL/XLPE/AWA/PVC
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.2 | 1.6 | 1.8 | 26 | 770 | 670 | 500 |
25 | 3.4 | 1.2 | 1.6 | 1.8 | 27 | 910 | 750 | 500 |
35 | 3.4 | 1.2 | 1.6 | 1.8 | 28 | 1,040 | 820 | 500 |
50 | 3.4 | 1.2 | 1.6 | 1.8 | 29 | 1,190 | 900 | 500 |
70 | 3.4 | 1.2 | 1.6 | 1.9 | 31 | 1,470 | 1,040 | 500 |
95 | 3.4 | 1.2 | 1.6 | 2.0 | 33 | 1,780 | 1,190 | 500 |
120 | 3.4 | 1.2 | 2.0 | 2.0 | 35 | 2,150 | 1,410 | 500 |
150 | 3.4 | 1.2 | 2.0 | 2.1 | 37 | 2,480 | 1,560 | 500 |
185 | 3.4 | 1.2 | 2.0 | 2.1 | 39 | 2,890 | 1,730 | 500 |
240 | 3.4 | 1.2 | 2.0 | 2.2 | 41 | 3,570 | 2,050 | 500 |
300 | 3.4 | 1.2 | 2.0 | 2.3 | 44 | 4,230 | 2,330 | 500 |
400 | 3.4 | 1.3 | 2.5 | 2.4 | 48 | 5,320 | 2,890 | 500 |
500 | 3.4 | 1.3 | 2.5 | 2.5 | 52 | 6,500 | 3,380 | 500 |
630 | 3.4 | 1.4 | 2.5 | 2.6 | 56 | 8,020 | 3,990 | 400 |
Three-core,CU/XLPE/SWA/PVC or AL/XLPE/SWA/PVC
Conductor Nominal Area | Insulation Thickness | Approx. Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.3 | 2.5 | 2.4 | 47 | 3,700 | 2,700 | 500 |
25 | 3.4 | 1.3 | 2.5 | 2.5 | 50 | 3,900 | 3,430 | 500 |
35 | 3.4 | 1.3 | 2.5 | 2.6 | 53 | 4,430 | 3,770 | 500 |
50 | 3.4 | 1.4 | 2.5 | 2.7 | 56 | 5,080 | 4,190 | 500 |
70 | 3.4 | 1.5 | 2.5 | 2.8 | 60 | 6,050 | 4,750 | 500 |
95 | 3.4 | 1.5 | 2.5 | 2.9 | 64 | 7,180 | 5,380 | 500 |
120 | 3.4 | 1.6 | 2.5 | 3.0 | 67 | 8,230 | 5,960 | 400 |
150 | 3.4 | 1.7 | 3.15 | 3.2 | 72 | 10,100 | 6,580 | 300 |
185 | 3.4 | 1.7 | 3.15 | 3.3 | 76 | 11,610 | 8,110 | 300 |
240 | 3.4 | 1.8 | 3.15 | 3.5 | 82 | 14,110 | 9,510 | 250 |
300 | 3.4 | 1.9 | 3.15 | 3.7 | 87 | 16,420 | 10,630 | 200 |
400 | 3.4 | 2.0 | 4.0 | 4.0 | 96 | 21,700 | 12,880 | 200 |
500 | 3.4 | 2.2 | 4.0 | 4.2 | 104 | 25,280 | 15,800 | 200 |
6/6kV,6/10(12)kV,XLPE Insulated Tape Armored PVC Sheathed Power Cable
Single-core,CU/XLPE/ATA/PVC or AL/XLPE/ATA/PVC
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.2 | 0.5 | 1.8 | 25 | 680 | 580 | 500 |
25 | 3.4 | 1.2 | 0.5 | 1.8 | 26 | 810 | 650 | 500 |
35 | 3.4 | 1.2 | 0.5 | 1.8 | 27 | 940 | 720 | 500 |
50 | 3.4 | 1.2 | 0.5 | 1.8 | 28 | 1,090 | 790 | 500 |
70 | 3.4 | 1.2 | 0.5 | 1.9 | 30 | 1,350 | 920 | 500 |
95 | 3.4 | 1.2 | 0.5 | 1.9 | 32 | 1,650 | 1,060 | 500 |
120 | 3.4 | 1.2 | 0.5 | 2.0 | 33 | 1,940 | 1,190 | 500 |
150 | 3.4 | 1.2 | 0.5 | 2.0 | 35 | 2,240 | 1,320 | 500 |
185 | 3.4 | 1.2 | 0.5 | 2.1 | 37 | 2,650 | 1,500 | 500 |
240 | 3.4 | 1.2 | 0.5 | 2.1 | 39 | 3,290 | 1,770 | 500 |
300 | 3.4 | 1.2 | 0.5 | 2.2 | 41 | 3,940 | 2,030 | 500 |
400 | 3.4 | 1.3 | 0.5 | 2.3 | 45 | 4,860 | 2,430 | 500 |
500 | 3.4 | 1.3 | 0.5 | 2.4 | 49 | 5,990 | 2,880 | 500 |
630 | 3.4 | 1.4 | 0.5 | 2.5 | 52 | 7,480 | 3,450 | 500 |
Three-core,CU/XLPE/STA/PVC or AL/XLPE/STA/PVC
Conductor Nominal Area | Insulation Thickness | Approx.Inner Covering Thickness | Armor Wire Size | Outer Sheath Thickness | Approx. Overall Diameter | Approx. Cable Weight | Standard Length Per Drum | |
Copper | Aluminum | |||||||
mm² | mm | mm | mm | mm | mm | kg/km | m | |
16 | 3.4 | 1.3 | 0.2 | 2.3 | 44 | 2,220 | 1,900 | 500 |
25 | 3.4 | 1.3 | 0.5 | 2.4 | 47 | 2,660 | 2,180 | 500 |
35 | 3.4 | 1.3 | 0.5 | 2.5 | 50 | 3,110 | 2,440 | 500 |
50 | 3.4 | 1.4 | 0.5 | 2.6 | 53 | 3,650 | 2,750 | 500 |
70 | 3.4 | 1.5 | 0.5 | 2.7 | 56 | 4,510 | 3,220 | 500 |
95 | 3.4 | 1.5 | 0.5 | 2.8 | 60 | 5,510 | 3,710 | 500 |
120 | 3.4 | 1.6 | 0.5 | 2.9 | 64 | 6,450 | 4,180 | 500 |
150 | 3.4 | 1.7 | 0.5 | 3.1 | 68 | 7,500 | 4,700 | 400 |
185 | 3.4 | 1.7 | 0.5 | 3.2 | 71 | 8,830 | 5,330 | 400 |
240 | 3.4 | 1.8 | 0.5 | 3.3 | 77 | 10,960 | 6,360 | 300 |
300 | 3.4 | 1.9 | 0.5 | 3.5 | 82 | 13,090 | 7,300 | 250 |
400 | 3.4 | 2.0 | 0.8 | 3.8 | 91 | 16,910 | 9,530 | 200 |
500 | 3.4 | 2.2 | 0.8 | 4.0 | 99 | 20,720 | 11,250 | 200 |
Packing & Shipping
- Packaging: Wooden drums or steel-reinforced reels with waterproof wrapping.
- Labeling: IEC-compliant markings (voltage, size, manufacturing date).
- Shipping: ISO-compliant containers with shockproof securing.
- Storage: Dry, ventilated environments; avoid direct sunlight.
Why choose us?
1. Export to many countries including Iraq, Tanzania and Australia and USA.
2. Best manufacturing and testing equipments imported from Germany, USA and Japan guarantee the best quality with competitive prices.
3. Professional overseas team guarantees you best pre-and-after sale services.
4. Experienced engineers and workers for more than 20 years ensure the quality and customized products.
5. 5S Management to enhance the qualifications of staff and make better service for customers.
6. Near Shanghai and Ningbo Port workshop makes it convenient to delivery on time.