YJV
8544601290
Type: Medium Voltage (MV) power cable, with voltage ratings ranging from 1kV to 36kV (focusing on 6kV, 6/10(12)kV)
Model: YJV
Code: 8544601290
Core Structure: High-purity copper/aluminum conductor (compliant with IEC 60228), conductor screen layer, XLPE/EPR insulation layer, insulation screen layer, metallic shield layer, outer sheath (PVC/LSZH/HDPE)
Cross Sectional Area: [25-630]mm²
Power Distribution Networks: Substations, transformers, and switchgear
Industrial Fields: Mining, oil & gas, and manufacturing facilities
Renewable Energy: Wind farms, solar parks, and hydropower stations
Infrastructure: Underground metro systems, airports, and hospitals
Efficiency: Low dielectric losses contribute to reduced energy waste, enhancing overall efficiency.
Durability: Resistant to moisture, chemicals, UV radiation, and abrasion, ensuring long-term performance in various environments.
Safety: Flame-retardant and low-smoke materials are used, making it suitable for confined spaces.
Flexibility: Armored (steel wire armoring SWA/tape armoring ATA) and non-armored options are available to meet different installation requirements.
Long Lifespan: >30 years under standard operating conditions.
International Standards: IEC 60502, IEC 60228
Industry Standards: IEEE 386, IEEE 575, AEIC CS8, NEMA WC 74
Normal Operation: XLPE (-40°C to +90°C); EPR (-50°C to +105°C)
Short-Circuit: Up to +250°C (both XLPE and EPR)
Property | Specification |
---|---|
Insulation Resistance | >1000 MΩ·km at 20°C |
Dielectric Strength | 3.5–30 kV/mm (depending on voltage grade) |
Fire Resistance | "IEC 60332 (flame retardant), IEC 61034 (low smoke)" |
Crush Resistance | >10 kN/m (tested per IEC 60229) |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|
Copper | Aluminum | |||||
16 | 3.4 | 1.8 | 20 | 450 | 350 | 500 |
25 | 3.4 | 1.8 | 21 | 560 | 400 | 500 |
35 | 3.4 | 1.8 | 22 | 680 | 460 | 500 |
50 | 3.4 | 1.8 | 24 | 810 | 520 | 500 |
70 | 3.4 | 1.8 | 25 | 1,050 | 620 | 500 |
95 | 3.4 | 1.8 | 27 | 1,320 | 730 | 500 |
120 | 3.4 | 1.8 | 28 | 1,580 | 840 | 500 |
150 | 3.4 | 1.9 | 30 | 1,880 | 960 | 500 |
185 | 3.4 | 1.9 | 32 | 2,250 | 1,100 | 500 |
240 | 3.4 | 2.0 | 34 | 2,870 | 1,350 | 500 |
300 | 3.4 | 2.1 | 37 | 3,490 | 1,580 | 500 |
400 | 3.4 | 2.2 | 40 | 4,350 | 1,920 | 500 |
500 | 3.4 | 2.3 | 44 | 5,440 | 2,320 | 500 |
630 | 3.4 | 2.4 | 48 | 6,860 | 2,830 | 500 |
800 | 3.4 | 2.5 | 52 | 8,600 | 3,430 | 400 |
1.000 | 3.4 | 2.6 | 56 | 10,630 | 4,150 | 300 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx.Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|
Copper | Aluminum | |||||
16 | 3.4 | 2.1 | 39 | 1,410 | 1,110 | 500 |
25 | 3.4 | 2.2 | 42 | 1,800 | 1,320 | 500 |
35 | 3.4 | 2.3 | 45 | 2,170 | 1,500 | 500 |
50 | 3.4 | 2.4 | 47 | 2,630 | 1,730 | 500 |
70 | 3.4 | 2.5 | 51 | 3,400 | 2,110 | 500 |
95 | 3.4 | 2.6 | 55 | 4,310 | 2,510 | 500 |
120 | 3.4 | 2.7 | 58 | 5,150 | 2,860 | 500 |
150 | 3.4 | 2.9 | 62 | 6,100 | 3,300 | 500 |
185 | 3.4 | 3.0 | 66 | 7,310 | 3,810 | 500 |
240 | 3.4 | 3.1 | 71 | 9,290 | 4,680 | 400 |
300 | 3.4 | 3.3 | 76 | 11,240 | 5,450 | 300 |
400 | 3.4 | 3.5 | 83 | 14,040 | 6,660 | 250 |
500 | 3.4 | 3.7 | 91 | 17,530 | 8,050 | 200 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Approx.Inner Covering Thickness (mm) | Armor Wire Size (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|---|---|
Copper | Aluminum | |||||||
16 | 3.4 | 1.2 | 1.6 | 1.8 | 26 | 770 | 670 | 500 |
25 | 3.4 | 1.2 | 1.6 | 1.8 | 27 | 910 | 750 | 500 |
35 | 3.4 | 1.2 | 1.6 | 1.8 | 28 | 1,040 | 820 | 500 |
50 | 3.4 | 1.2 | 1.6 | 1.8 | 29 | 1,190 | 900 | 500 |
70 | 3.4 | 1.2 | 1.6 | 1.9 | 31 | 1,470 | 1,040 | 500 |
95 | 3.4 | 1.2 | 1.6 | 2.0 | 33 | 1,780 | 1,190 | 500 |
120 | 3.4 | 1.2 | 2.0 | 2.0 | 35 | 2,150 | 1,410 | 500 |
150 | 3.4 | 1.2 | 2.0 | 2.1 | 37 | 2,480 | 1,560 | 500 |
185 | 3.4 | 1.2 | 2.0 | 2.1 | 39 | 2,890 | 1,730 | 500 |
240 | 3.4 | 1.2 | 2.0 | 2.2 | 41 | 3,570 | 2,050 | 500 |
300 | 3.4 | 1.2 | 2.0 | 2.3 | 44 | 4,230 | 2,330 | 500 |
400 | 3.4 | 1.3 | 2.5 | 2.4 | 48 | 5,320 | 2,890 | 500 |
500 | 3.4 | 1.3 | 2.5 | 2.5 | 52 | 6,500 | 3,380 | 500 |
630 | 3.4 | 1.4 | 2.5 | 2.6 | 56 | 8,020 | 3,990 | 400 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Approx. Inner Covering Thickness (mm) | Armor Wire Size (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|---|---|
Copper | Aluminum | |||||||
16 | 3.4 | 1.3 | 2.5 | 2.4 | 47 | 3,700 | 2,700 | 500 |
25 | 3.4 | 1.3 | 2.5 | 2.5 | 50 | 3,900 | 3,430 | 500 |
35 | 3.4 | 1.3 | 2.5 | 2.6 | 53 | 4,430 | 3,770 | 500 |
50 | 3.4 | 1.4 | 2.5 | 2.7 | 56 | 5,080 | 4,190 | 500 |
70 | 3.4 | 1.5 | 2.5 | 2.8 | 60 | 6,050 | 4,750 | 500 |
95 | 3.4 | 1.5 | 2.5 | 2.9 | 64 | 7,180 | 5,380 | 500 |
120 | 3.4 | 1.6 | 2.5 | 3.0 | 67 | 8,230 | 5,960 | 400 |
150 | 3.4 | 1.7 | 3.15 | 3.2 | 72 | 10,100 | 6,580 | 300 |
185 | 3.4 | 1.7 | 3.15 | 3.3 | 76 | 11,610 | 8,110 | 300 |
240 | 3.4 | 1.8 | 3.15 | 3.5 | 82 | 14,110 | 9,510 | 250 |
300 | 3.4 | 1.9 | 3.15 | 3.7 | 87 | 16,420 | 10,630 | 200 |
400 | 3.4 | 2.0 | 4.0 | 4.0 | 96 | 21,700 | 12,880 | 200 |
500 | 3.4 | 2.2 | 4.0 | 4.2 | 104 | 25,280 | 15,800 | 200 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Approx.Inner Covering Thickness (mm) | Armor Wire Size (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|---|---|
Copper | Aluminum | |||||||
16 | 3.4 | 1.2 | 0.5 | 1.8 | 25 | 680 | 580 | 500 |
25 | 3.4 | 1.2 | 0.5 | 1.8 | 26 | 810 | 650 | 500 |
35 | 3.4 | 1.2 | 0.5 | 1.8 | 27 | 940 | 720 | 500 |
50 | 3.4 | 1.2 | 0.5 | 1.8 | 28 | 1,090 | 790 | 500 |
70 | 3.4 | 1.2 | 0.5 | 1.9 | 30 | 1,350 | 920 | 500 |
95 | 3.4 | 1.2 | 0.5 | 1.9 | 32 | 1,650 | 1,060 | 500 |
120 | 3.4 | 1.2 | 0.5 | 2.0 | 33 | 1,940 | 1,190 | 500 |
150 | 3.4 | 1.2 | 0.5 | 2.0 | 35 | 2,240 | 1,320 | 500 |
185 | 3.4 | 1.2 | 0.5 | 2.1 | 37 | 2,650 | 1,500 | 500 |
240 | 3.4 | 1.2 | 0.5 | 2.1 | 39 | 3,290 | 1,770 | 500 |
300 | 3.4 | 1.2 | 0.5 | 2.2 | 41 | 3,940 | 2,030 | 500 |
400 | 3.4 | 1.3 | 0.5 | 2.3 | 45 | 4,860 | 2,430 | 500 |
500 | 3.4 | 1.3 | 0.5 | 2.4 | 49 | 5,990 | 2,880 | 500 |
630 | 3.4 | 1.4 | 0.5 | 2.5 | 52 | 7,480 | 3,450 | 500 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Approx.Inner Covering Thickness (mm) | Armor Wire Size (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|---|---|
Copper | Aluminum | |||||||
16 | 3.4 | 1.3 | 0.2 | 2.3 | 44 | 2,220 | 1,900 | 500 |
25 | 3.4 | 1.3 | 0.5 | 2.4 | 47 | 2,660 | 2,180 | 500 |
35 | 3.4 | 1.3 | 0.5 | 2.5 | 50 | 3,110 | 2,440 | 500 |
50 | 3.4 | 1.4 | 0.5 | 2.6 | 53 | 3,650 | 2,750 | 500 |
70 | 3.4 | 1.5 | 0.5 | 2.7 | 56 | 4,510 | 3,220 | 500 |
95 | 3.4 | 1.5 | 0.5 | 2.8 | 60 | 5,510 | 3,710 | 500 |
120 | 3.4 | 1.6 | 0.5 | 2.9 | 64 | 6,450 | 4,180 | 500 |
150 | 3.4 | 1.7 | 0.5 | 3.1 | 68 | 7,500 | 4,700 | 400 |
185 | 3.4 | 1.7 | 0.5 | 3.2 | 71 | 8,830 | 5,330 | 400 |
240 | 3.4 | 1.8 | 0.5 | 3.3 | 77 | 10,960 | 6,360 | 300 |
300 | 3.4 | 1.9 | 0.5 | 3.5 | 82 | 13,090 | 7,300 | 250 |
400 | 3.4 | 2.0 | 0.8 | 3.8 | 91 | 16,910 | 9,530 | 200 |
500 | 3.4 | 2.2 | 0.8 | 4.0 | 99 | 20,720 | 11,250 | 200 |
Packaging: Wooden drums or steel-reinforced reels with waterproof wrapping.
Labeling: IEC-compliant markings including voltage, size, and manufacturing date.
Shipping: ISO-compliant containers with shockproof securing.
Storage: Should be stored in dry, ventilated environments and avoid direct sunlight.
Type: Medium Voltage (MV) power cable, with voltage ratings ranging from 1kV to 36kV (focusing on 6kV, 6/10(12)kV)
Model: YJV
Code: 8544601290
Core Structure: High-purity copper/aluminum conductor (compliant with IEC 60228), conductor screen layer, XLPE/EPR insulation layer, insulation screen layer, metallic shield layer, outer sheath (PVC/LSZH/HDPE)
Cross Sectional Area: [25-630]mm²
Power Distribution Networks: Substations, transformers, and switchgear
Industrial Fields: Mining, oil & gas, and manufacturing facilities
Renewable Energy: Wind farms, solar parks, and hydropower stations
Infrastructure: Underground metro systems, airports, and hospitals
Efficiency: Low dielectric losses contribute to reduced energy waste, enhancing overall efficiency.
Durability: Resistant to moisture, chemicals, UV radiation, and abrasion, ensuring long-term performance in various environments.
Safety: Flame-retardant and low-smoke materials are used, making it suitable for confined spaces.
Flexibility: Armored (steel wire armoring SWA/tape armoring ATA) and non-armored options are available to meet different installation requirements.
Long Lifespan: >30 years under standard operating conditions.
International Standards: IEC 60502, IEC 60228
Industry Standards: IEEE 386, IEEE 575, AEIC CS8, NEMA WC 74
Normal Operation: XLPE (-40°C to +90°C); EPR (-50°C to +105°C)
Short-Circuit: Up to +250°C (both XLPE and EPR)
Property | Specification |
---|---|
Insulation Resistance | >1000 MΩ·km at 20°C |
Dielectric Strength | 3.5–30 kV/mm (depending on voltage grade) |
Fire Resistance | "IEC 60332 (flame retardant), IEC 61034 (low smoke)" |
Crush Resistance | >10 kN/m (tested per IEC 60229) |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|
Copper | Aluminum | |||||
16 | 3.4 | 1.8 | 20 | 450 | 350 | 500 |
25 | 3.4 | 1.8 | 21 | 560 | 400 | 500 |
35 | 3.4 | 1.8 | 22 | 680 | 460 | 500 |
50 | 3.4 | 1.8 | 24 | 810 | 520 | 500 |
70 | 3.4 | 1.8 | 25 | 1,050 | 620 | 500 |
95 | 3.4 | 1.8 | 27 | 1,320 | 730 | 500 |
120 | 3.4 | 1.8 | 28 | 1,580 | 840 | 500 |
150 | 3.4 | 1.9 | 30 | 1,880 | 960 | 500 |
185 | 3.4 | 1.9 | 32 | 2,250 | 1,100 | 500 |
240 | 3.4 | 2.0 | 34 | 2,870 | 1,350 | 500 |
300 | 3.4 | 2.1 | 37 | 3,490 | 1,580 | 500 |
400 | 3.4 | 2.2 | 40 | 4,350 | 1,920 | 500 |
500 | 3.4 | 2.3 | 44 | 5,440 | 2,320 | 500 |
630 | 3.4 | 2.4 | 48 | 6,860 | 2,830 | 500 |
800 | 3.4 | 2.5 | 52 | 8,600 | 3,430 | 400 |
1.000 | 3.4 | 2.6 | 56 | 10,630 | 4,150 | 300 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx.Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|
Copper | Aluminum | |||||
16 | 3.4 | 2.1 | 39 | 1,410 | 1,110 | 500 |
25 | 3.4 | 2.2 | 42 | 1,800 | 1,320 | 500 |
35 | 3.4 | 2.3 | 45 | 2,170 | 1,500 | 500 |
50 | 3.4 | 2.4 | 47 | 2,630 | 1,730 | 500 |
70 | 3.4 | 2.5 | 51 | 3,400 | 2,110 | 500 |
95 | 3.4 | 2.6 | 55 | 4,310 | 2,510 | 500 |
120 | 3.4 | 2.7 | 58 | 5,150 | 2,860 | 500 |
150 | 3.4 | 2.9 | 62 | 6,100 | 3,300 | 500 |
185 | 3.4 | 3.0 | 66 | 7,310 | 3,810 | 500 |
240 | 3.4 | 3.1 | 71 | 9,290 | 4,680 | 400 |
300 | 3.4 | 3.3 | 76 | 11,240 | 5,450 | 300 |
400 | 3.4 | 3.5 | 83 | 14,040 | 6,660 | 250 |
500 | 3.4 | 3.7 | 91 | 17,530 | 8,050 | 200 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Approx.Inner Covering Thickness (mm) | Armor Wire Size (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|---|---|
Copper | Aluminum | |||||||
16 | 3.4 | 1.2 | 1.6 | 1.8 | 26 | 770 | 670 | 500 |
25 | 3.4 | 1.2 | 1.6 | 1.8 | 27 | 910 | 750 | 500 |
35 | 3.4 | 1.2 | 1.6 | 1.8 | 28 | 1,040 | 820 | 500 |
50 | 3.4 | 1.2 | 1.6 | 1.8 | 29 | 1,190 | 900 | 500 |
70 | 3.4 | 1.2 | 1.6 | 1.9 | 31 | 1,470 | 1,040 | 500 |
95 | 3.4 | 1.2 | 1.6 | 2.0 | 33 | 1,780 | 1,190 | 500 |
120 | 3.4 | 1.2 | 2.0 | 2.0 | 35 | 2,150 | 1,410 | 500 |
150 | 3.4 | 1.2 | 2.0 | 2.1 | 37 | 2,480 | 1,560 | 500 |
185 | 3.4 | 1.2 | 2.0 | 2.1 | 39 | 2,890 | 1,730 | 500 |
240 | 3.4 | 1.2 | 2.0 | 2.2 | 41 | 3,570 | 2,050 | 500 |
300 | 3.4 | 1.2 | 2.0 | 2.3 | 44 | 4,230 | 2,330 | 500 |
400 | 3.4 | 1.3 | 2.5 | 2.4 | 48 | 5,320 | 2,890 | 500 |
500 | 3.4 | 1.3 | 2.5 | 2.5 | 52 | 6,500 | 3,380 | 500 |
630 | 3.4 | 1.4 | 2.5 | 2.6 | 56 | 8,020 | 3,990 | 400 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Approx. Inner Covering Thickness (mm) | Armor Wire Size (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|---|---|
Copper | Aluminum | |||||||
16 | 3.4 | 1.3 | 2.5 | 2.4 | 47 | 3,700 | 2,700 | 500 |
25 | 3.4 | 1.3 | 2.5 | 2.5 | 50 | 3,900 | 3,430 | 500 |
35 | 3.4 | 1.3 | 2.5 | 2.6 | 53 | 4,430 | 3,770 | 500 |
50 | 3.4 | 1.4 | 2.5 | 2.7 | 56 | 5,080 | 4,190 | 500 |
70 | 3.4 | 1.5 | 2.5 | 2.8 | 60 | 6,050 | 4,750 | 500 |
95 | 3.4 | 1.5 | 2.5 | 2.9 | 64 | 7,180 | 5,380 | 500 |
120 | 3.4 | 1.6 | 2.5 | 3.0 | 67 | 8,230 | 5,960 | 400 |
150 | 3.4 | 1.7 | 3.15 | 3.2 | 72 | 10,100 | 6,580 | 300 |
185 | 3.4 | 1.7 | 3.15 | 3.3 | 76 | 11,610 | 8,110 | 300 |
240 | 3.4 | 1.8 | 3.15 | 3.5 | 82 | 14,110 | 9,510 | 250 |
300 | 3.4 | 1.9 | 3.15 | 3.7 | 87 | 16,420 | 10,630 | 200 |
400 | 3.4 | 2.0 | 4.0 | 4.0 | 96 | 21,700 | 12,880 | 200 |
500 | 3.4 | 2.2 | 4.0 | 4.2 | 104 | 25,280 | 15,800 | 200 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Approx.Inner Covering Thickness (mm) | Armor Wire Size (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|---|---|
Copper | Aluminum | |||||||
16 | 3.4 | 1.2 | 0.5 | 1.8 | 25 | 680 | 580 | 500 |
25 | 3.4 | 1.2 | 0.5 | 1.8 | 26 | 810 | 650 | 500 |
35 | 3.4 | 1.2 | 0.5 | 1.8 | 27 | 940 | 720 | 500 |
50 | 3.4 | 1.2 | 0.5 | 1.8 | 28 | 1,090 | 790 | 500 |
70 | 3.4 | 1.2 | 0.5 | 1.9 | 30 | 1,350 | 920 | 500 |
95 | 3.4 | 1.2 | 0.5 | 1.9 | 32 | 1,650 | 1,060 | 500 |
120 | 3.4 | 1.2 | 0.5 | 2.0 | 33 | 1,940 | 1,190 | 500 |
150 | 3.4 | 1.2 | 0.5 | 2.0 | 35 | 2,240 | 1,320 | 500 |
185 | 3.4 | 1.2 | 0.5 | 2.1 | 37 | 2,650 | 1,500 | 500 |
240 | 3.4 | 1.2 | 0.5 | 2.1 | 39 | 3,290 | 1,770 | 500 |
300 | 3.4 | 1.2 | 0.5 | 2.2 | 41 | 3,940 | 2,030 | 500 |
400 | 3.4 | 1.3 | 0.5 | 2.3 | 45 | 4,860 | 2,430 | 500 |
500 | 3.4 | 1.3 | 0.5 | 2.4 | 49 | 5,990 | 2,880 | 500 |
630 | 3.4 | 1.4 | 0.5 | 2.5 | 52 | 7,480 | 3,450 | 500 |
Conductor Nominal Area (mm²) | Insulation Thickness (mm) | Approx.Inner Covering Thickness (mm) | Armor Wire Size (mm) | Outer Sheath Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Cable Weight (kg/km) | Standard Length Per Drum (m) | |
---|---|---|---|---|---|---|---|---|
Copper | Aluminum | |||||||
16 | 3.4 | 1.3 | 0.2 | 2.3 | 44 | 2,220 | 1,900 | 500 |
25 | 3.4 | 1.3 | 0.5 | 2.4 | 47 | 2,660 | 2,180 | 500 |
35 | 3.4 | 1.3 | 0.5 | 2.5 | 50 | 3,110 | 2,440 | 500 |
50 | 3.4 | 1.4 | 0.5 | 2.6 | 53 | 3,650 | 2,750 | 500 |
70 | 3.4 | 1.5 | 0.5 | 2.7 | 56 | 4,510 | 3,220 | 500 |
95 | 3.4 | 1.5 | 0.5 | 2.8 | 60 | 5,510 | 3,710 | 500 |
120 | 3.4 | 1.6 | 0.5 | 2.9 | 64 | 6,450 | 4,180 | 500 |
150 | 3.4 | 1.7 | 0.5 | 3.1 | 68 | 7,500 | 4,700 | 400 |
185 | 3.4 | 1.7 | 0.5 | 3.2 | 71 | 8,830 | 5,330 | 400 |
240 | 3.4 | 1.8 | 0.5 | 3.3 | 77 | 10,960 | 6,360 | 300 |
300 | 3.4 | 1.9 | 0.5 | 3.5 | 82 | 13,090 | 7,300 | 250 |
400 | 3.4 | 2.0 | 0.8 | 3.8 | 91 | 16,910 | 9,530 | 200 |
500 | 3.4 | 2.2 | 0.8 | 4.0 | 99 | 20,720 | 11,250 | 200 |
Packaging: Wooden drums or steel-reinforced reels with waterproof wrapping.
Labeling: IEC-compliant markings including voltage, size, and manufacturing date.
Shipping: ISO-compliant containers with shockproof securing.
Storage: Should be stored in dry, ventilated environments and avoid direct sunlight.