Home » Products » Cables » Power Cable » 0.6/1kV Australia NZ Standard ABC Cable

0.6/1kV Australia NZ Standard ABC Cable

5 0 Reviews
0.6/1kV Aerial Bundled Cable (ABC)
Designed for reliable overhead power distribution in harsh environments, our Aerial Bundled Cable (ABC) complies with AS/NZS 3560.1 standards, ensuring durability, safety, and exceptional performance in Australian and New Zealand climates. Ideal for rural and urban power networks, this cable combines UV-resistant insulation, corrosion-proof design, and easy installation to reduce maintenance costs and enhance grid reliability.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button


0.6/1kV Aerial Bundled Cable (ABC) – AS/NZS 3560.1 Compliant

Product Overview

East Energy Electrical Engineering presents the 0.6/1kV Aerial Bundled Cable (ABC) – a high-performance overhead power distribution solution engineered exclusively to meet AS/NZS 3560.1 standards – the benchmark for reliability in Australian and New Zealand climates.

This cable integrates advanced manufacturing craftsmanship with premium materials to deliver exceptional durability, making it ideal for both rural and urban power networks facing harsh environmental conditions, including:

  • Extreme heat (Australian outback, desert regions)

  • High humidity (coastal Queensland, tropical North Queensland)

  • Alpine cold (New Zealand South Island, Snowy Mountains)

  • High wind zones (cyclone-prone areas, coastal exposure)

  • High UV exposure (Australian and New Zealand summer conditions)


Core Construction

At its core, the cable features:

Component Material Options Key Property
Phase conductors Aluminum alloy (AAAC) or aluminum (AAC) High conductivity, lightweight, corrosion-resistant
Neutral messenger Aluminum alloy (integrated) Optional, simplifies installation
Insulation UV-resistant cross-linked polyethylene (XLPE) Excellent electrical properties, thermal stability
Outer jacket Black high-density polyethylene (HDPE) Maximum mechanical and environmental protection

Insulation and jacket features:

  • UV-resistant XLPE – prevents degradation from prolonged sun exposure

  • Black HDPE jacket – provides abrasion resistance, moisture barrier, and chemical protection

  • Flame-retardant properties – per IEC 60332-1 (self-extinguishing)


Innovative Design

The innovative design includes:

  • Optional integrated neutral messenger wire – simplifying installation while ensuring compliance with strict grounding requirements

  • Compact bundling – multiple insulated conductors twisted together for space efficiency

  • Color-coded phase identification – red, white, blue for 3-phase; black for neutral (per AS/NZS standard)


Temperature Range and Environmental Performance

Parameter Value
Continuous operating temperature –40°C to +90°C
Maximum short-circuit temperature 250°C (for up to 5 seconds)
Minimum installation temperature –5°C (cable must be pre-warmed below 0°C)
Flame retardancy IEC 60332-1 (self-extinguishing)

This ABC cable excels in extreme heat, cold, and high-humidity environments – from coastal regions to alpine areas, including:

  • Coastal installations (salt spray, high humidity, cyclonic winds)

  • Desert environments (UV exposure, extreme daytime heat)

  • Mountainous terrain (low temperatures, ice loading, high winds)

  • Urban networks (space-constrained overhead installations)


Applications

Rural Power Networks

  • Farm electrification – supplying power to remote properties, irrigation pumps, and shearing sheds

  • Outback communities – reliable power distribution in remote and isolated areas

  • Mining sites – temporary and permanent overhead power supply

  • Telecommunication towers – power supply for remote base stations

Urban Power Distribution

  • Residential subdivisions – overhead supply to new housing developments

  • Commercial areas – shopping centers, industrial estates, business parks

  • Street lighting – power supply for public lighting systems

  • Renewable energy connections – solar farm and wind farm grid connections

Special Applications

  • Coastal resorts – salt-resistant construction for marine environments

  • Alpine villages – low-temperature performance for ski resorts and mountain communities

  • Industrial zones – high current capacity for factory and warehouse power supply



0.6/1kV Australia NZ Standard ABC Cable



Advantages of ABC vs Traditional Bare Overhead Conductors

Feature Aerial Bundled Cable (ABC) Bare Overhead Conductor
Safety Insulated conductors reduce shock risk Exposed conductors, high shock risk
Tree contact No fault (insulated) Short circuit or ground fault
Installation Pre-bundled, faster deployment Separate wires, requires cross-arms
Pole spacing Longer spans possible Shorter spans due to sag limitations
Clearance Reduced clearance requirements Larger clearance needed
Corrosion resistance Excellent (HDPE jacket) Good (galvanized or bare)
Maintenance Minimal (no tree trimming urgency) Regular tree trimming required
Cost Higher initial cost Lower initial cost
Lifecycle cost Lower (less maintenance) Higher (ongoing maintenance)

Compliance and Certifications

Standard Description Compliance
AS/NZS 3560.1 Aerial bundled cables for overhead distribution ✅ Full compliance
AS/NZS 3808 Insulation and sheathing materials ✅ Full compliance
IEC 60332-1 Flame retardancy test ✅ Compliant
IEC 60502 Power cables with extruded insulation ✅ Compliant
AS/NZS 1125 Conductors for overhead lines ✅ Compliant

Technical Specifications

Parameter Value
Rated voltage (U₀/U) 0.6/1 kV
System frequency 50 Hz
Conductor material AAAC (aluminum alloy) or AAC (aluminum)
Insulation material XLPE (cross-linked polyethylene)
Outer jacket material HDPE (high-density polyethylene)
UV resistance Yes (UV-stabilized XLPE and HDPE)
Flame retardancy IEC 60332-1
Continuous operating temperature –40°C to +90°C
Short-circuit temperature 250°C (max 5 seconds)
Minimum bending radius 8 × cable diameter (during installation)
Maximum pulling tension 50 N/mm² of conductor cross-section

Available Configurations

Configuration Phase Conductors Neutral Messenger Application
Duplex 2 × insulated 1 × bare or insulated Single-phase, street lighting
Triplex 3 × insulated 1 × bare or insulated Three-phase, residential
Quadruplex 3 × insulated + 1 × insulated neutral Integrated Three-phase with neutral
Single-core 1 × insulated N/A Individual phase runs

Conductor sizes available:

  • 16 mm², 25 mm², 35 mm², 50 mm², 70 mm², 95 mm², 120 mm², 150 mm², 185 mm², 240 mm²

Custom configurations available upon request.


Installation Guidelines

Preparation

  • Cable handling – avoid dragging over sharp edges; use rollers for long pulls

  • Minimum bending radius – 8 × cable diameter (installation), 6 × cable diameter (fixed)

  • Temperature – do not install below –5°C without pre-warming

Pole Mounting

  • Suspension clamps – use ABC-specific clamps to avoid insulation damage

  • Dead-end clamps – use pre-formed dead-ends or compression dead-ends

  • Pole spacing – typical 50–80 meters depending on conductor size and local wind/ice conditions

Jointing and Termination

  • Joints – use ABC-specific joints with insulation restoration

  • Terminations – use ABC termination kits (indoor or outdoor)

  • Grounding – connect neutral messenger to pole ground at regular intervals (per AS/NZS 3560.1)


Packing and Delivery

Packaging Type Length Application
Wooden drum 500 m, 1,000 m, 1,500 m Standard for project delivery
Plastic reel 100 m, 200 m Small projects, retail
Custom length As required Large projects

Shipping methods:

  • Sea freight – standard for large quantities (20' or 40' containers)

  • Air freight – for urgent or small orders

  • Land freight – regional delivery

Documentation included:

  • Packing list

  • Commercial invoice

  • Test reports (routine and type tests)

  • Quality certificate

  • Installation manual




Code: ABC 0.6/1kV.

Standards:HD 626  S1:1996  Part5-Section D,AMKA(SFS     2200).

Construction: Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral Messenger:Aluminum conductors.

Application: Aerial Bundled Conductors are used for tributary networks of power buildings and their internal networks.

Installation: These cables are not allowed to be buried, even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.4

±0.05

1.4


7.1

7.3

70


25

5.9

±0.02

1.4


8.3

9.1

95


35

6.9

±0.02

1.6


9.7

10.5

115


50

8.1

±0.25

1.6


10.8

11.8

140


70

9.7

±0.25

1.8


12.8

13.8

180


120

12.8

±0.30

2.0


16.2

17.4

250


*  Defined  for  ambient  temperature  of 25℃  and  max.conductor  temperature  of 70℃.

Cross Section

Conductor Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


25

5.9

±0.02



5.5

6.3


7.4

35

6.9

±0.02



6.5

7.3


10.3

50

8.1

±0.25



7.6

8.6


14.2

70

9.7

±0.25



9.2

10.2


20.6

95

11.4

±0.30



10.8

12.0


27.9

Dimensions     of     Cable     Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+ Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

1×16+25

15

3×16+25

22

4×16+25

22

3×25+35

26

4×25+35

26

3×35+50

30

3×50+70

35

3×70+95

41

3×120+95

47

LV-ABC Lines with Insulated Neutral Messenger

Code: ABC 0.6/1kV.

Standards:HD 626 S1:1996 Part 6-Section E,AMKA(SFS 2200)

Construction: Aluminum conductors with XLPE  insulation.

Application:Aerial Bundled Conductors are used for tributary networks of power     buildings and their internal networks.

Installation:These cables are not allowed to be buried,even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameten

Current Carrying Capacity

Breaking Load

(mm²)

min.

max.

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.6

5.1

1.2


7.0

7.8



25

5.8

6.3

1.4


8.6

9.4

112


35

6.8

7.3

1.6


10.0

10.9

138


50

7.9

8.4

1.6


11.1

12.0

168


70

9.7

10.2

1.8


13.3

14.2

213


95

11.0

12.0

1.8


14.6

15.7

258


120

12.0

13.1

1.8


15.6

16.7

306


150

13.9

15.0

1.7


17.3

18.6

344


* Defined for ambient temperature of 30℃ and max. conductor temperature of 90℃.

Dimensions of Neutral Messenger Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


54.6

9.2

9.6

1.6


12.3

13.0


16.6

70

10.0

10.2

1.5


12.9

13.6


20.5

95

12.2

12.9

1.6


15.3

16.3


27.5

* Defined for ambient temperature of 30℃ and max.conductor temperature of 90℃.

Dimensions of Cable Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

3×25+54.6

30.0

3×35+K×16+54.6

33.0

3×50+K×16+54.6

36.0

3×70+K×16+54.6

37.5

3×70+K×25+54.6

40.0

3×70+K×16+70

41.0

3×95+K×16+70

44.0

3×120+K×16+70

46.0

3×120+K×16+95

47.0

3×150+K×16+70

48.0

3×150+K×16+95

49.0

* Note: K number of public lighting conductors(K can be equal to 0.1.2.or 3).

Code: ABC 11kV.

Standards:SANS 1713.

Construction:Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral  Messenger:A  stranded  galvanized  steel  conductor  with  XLPE insulation.

Application: The Aerial Bundled Conductors shall suitable for continuous

operation outdoors in tropical areas at altitudes of up to 2200m above sea

level, humidity of up to 90%, average ambient temperature of+30℃ with

a minimum of - 1℃ and a maximum of +4℃ in direct  sunlight, heavy

saline  conditions  along  the  coast  and  isoceraunic  levels  of up  to  180

thunderstorm days per year.

Installation:These cables are not allowed to be buried,even in conduits.


Phase Conductor Characteristics

1

Conductor    size

mm²

70

95

185

2

Diameter    over    conductor.nominal

mm

9.3-10.2

11.6

16.4


3

Thickness   of   dielectric.nominal

mm

3.4

3.4

3.4

Minimum  at  a  point

mm

2.96

2.96

2.96

4

Diameter  over  insulation.  nominal

mm

16.1-17.0

21.3

25.9

5

Diameter  over  semi-conducting  core  screen.  nominal

mm

18.1-19

23.3

27.9

6

Thickness  of  copper  tape.nominal

mm

0.15

1.15

2.15


7

Thickness   of   sheath.nominal

mm

1.8

1.8

1.8

Minimum  at  a  point

mm

1.43

1.43

1.51

8

Catenary   size

mm²

50

50

70

9

Overall   diameter   of   bundle.nominal

mm

55.7

67.8

79.2

10

Nominal  mass

kg/m

2.64

3.25

4.65


Supporting Catenary Characteristics

1

Catenary size

mm²

50

70

2

Number of wires


7

7

3

Wire size(diameter)

mm

3.0

3.6

4

Minimum tensile strength of each wire

kN

9.26

13.13

5

Elongation at break. minimum

%

3.5

4.0


6

Thickness of protective covering




Nominal

mm

1.2

1.2

Minimum at a point

mm

0.96

1.96

7

Impusewhsandvoag        e1.250s


21kV/5min

21kV/5min


Previous: 
Next: 
Keep In Touch With Us

ABOUT US

Our company is a professional company that engaged in production, sales, technology research, technology development and technical services of electrical system products, power engineering design and construction, electrical products, electrical equipment, sales, installation and technical services of energy storage equipment.
 

PRODUCTS

CONTACT US

  Mainland China Office
2201-7 & 2201-8, Dongjiu Building, No.888 Jiefang East Road, Yixing City, Jiangsu Province, China
  +86-510-87013147
  Hong Kong Office
Flat A,7/F.,Annking Industrial Building,22 Wang Yip Street East,Yuen Long,N.T.,Hong Kong
  +852-84960208
​Copyright ©  2025 East Energy Electrical Engineering Co., Ltd.  苏ICP备16064163号-1 Technology by Leadong. Sitemap.