Home » Products » Cables » Power Cable » 0.6/1kV Australia NZ Standard ABC Cable

0.6/1kV Australia NZ Standard ABC Cable

5 0 Reviews
0.6/1kV Aerial Bundled Cable (ABC)
Designed for reliable overhead power distribution in harsh environments, our Aerial Bundled Cable (ABC) complies with AS/NZS 3560.1 standards, ensuring durability, safety, and exceptional performance in Australian and New Zealand climates. Ideal for rural and urban power networks, this cable combines UV-resistant insulation, corrosion-proof design, and easy installation to reduce maintenance costs and enhance grid reliability.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button


Product Overview


East Energy Electrical Engineering presents the 0.6/1kV Aerial Bundled Cable (ABC), a high-performance overhead power distribution solution engineered exclusively to meet AS/NZS 3560.1 standards—the benchmark for reliability in Australian and New Zealand climates. This cable integrates advanced manufacturing 工艺 (craftsmanship) with premium materials to deliver exceptional durability, making it ideal for both rural and urban power networks facing harsh environmental conditions.


At its core, the cable features aluminum alloy (AAAC) or aluminum (AAC) conductors wrapped in UV-resistant cross-linked polyethylene (XLPE) insulation, paired with a black high-density polyethylene (HDPE) jacket for maximum protection. The innovative design includes an optional integrated neutral messenger wire, simplifying installation while ensuring compliance with strict grounding requirements. With a temperature range of -40°C to +90°C and flame-retardant properties (per IEC 60332-1), this ABC cable excels in extreme heat, cold, and high-humidity environments—from coastal regions to alpine areas.


0.6/1kV Australia NZ Standard ABC Cable



Parameter

Specification

Standard AS/NZS 3560.1, IEC 60502-1
Rated Voltage 0.6/1kV
Conductor Material Aluminum Alloy (AAAC) / Aluminum (AAC)
Insulation Material UV-resistant Cross-linked Polyethylene (XLPE)
Jacket Material Black HDPE (High-Density Polyethylene)
Core Configuration 3/4/5 Cores + Integrated Neutral Messenger Wire (Optional)
Temperature Range -40°C to +90°C
Minimum Bending Radius 10 × Cable Diameter
Tensile Strength ≥120 MPa (AAAC) / ≥60 MPa (AAC)
Fire Performance Flame-retardant (IEC 60332-1)


Available Sizes


Model Conductor Size (mm²) Insulation Thickness (mm) Overall Diameter (mm) Approx. Weight (kg/km)
ABC-3×16+NM16 16 1.4 22.5 320
ABC-4×25+NM25 25 1.6 28.0 480
ABC-5×50+NM50 50 2.0 35.5 820


0.6/1kV Aerial Bunched Cable(ABC)(Australia/New Zealand Standard)


Nominal area

Number/Dia.

Insulation thickness

mm²

mm

mm

2/4*16

7/1.72

1.3

2/3/4*25

7/2.20

1.3

2/3/4*35

7/2.58

1.3

2/3/4*50

7/3.00

1.5

4*70

19/2.1

4.5

1/4*95

19/2.58

1.7

4*120

19/2.9

1.7


Product Benefits


Superior Durability & Weather Resistance

The UV-stabilized XLPE insulation and anti-oxidation conductor coating prevent degradation from prolonged sun exposure, salt spray, and humidity—extending the cable’s service life to over 30 years in coastal, desert, and alpine regions. This durability directly reduces long-term maintenance costs for power utilities.


Enhanced Safety & Compliance

Compliance with AS/NZS 3560.1 and IEC 60502-1 standards ensures the cable meets global safety benchmarks. The integrated neutral messenger wire eliminates the need for separate grounding components, reducing installation complexity and minimizing safety risks during setup.


Easy Installation & Labor Savings

Pre-assembled cable bundles cut on-site labor time by 40% compared to traditional overhead wiring. The cable’s flexible design (minimum bending radius of 10× cable diameter) allows for easy routing around obstacles, making it suitable for fast-paced construction projects.


Customization & OEM Capabilities

East Energy offers tailored solutions to match specific project needs, including custom core configurations, conductor sizes (16mm² to 120mm²), and insulation thicknesses. Our OEM services enable branding alignment and technical adjustments to meet unique regional or client requirements.


Usage


Overhead Power Distribution

The 0.6/1kV ABC cable is the primary choice for overhead power networks in:

Rural areas: Reliable power delivery to remote communities with limited maintenance access.

Suburban zones: Safe integration with residential and commercial infrastructure.

Industrial sites: Heavy-duty performance for factories and manufacturing facilities.


Renewable Energy Projects & Temporary Power Supply

It supports clean energy initiatives by connecting solar farms and wind turbines to the main grid, with weather-resistant properties ensuring consistent performance in outdoor renewable installations.

Ideal for construction sites and emergency response scenarios, the cable’s quick installation and robust design provide temporary, stable power without compromising safety.


Why Choose Us


Certified Quality & Independent Testing

Our ABC cables undergo rigorous testing by global authorities SGS and Intertek to verify compliance with AS/NZS 3560.1—guaranteeing reliability and performance. Every batch meets strict quality control standards to avoid defects.


Expertise in Australia/New Zealand Markets

With years of experience supplying to Australian and New Zealand clients, we understand local climate challenges and regulatory requirements. Our team provides tailored technical support to ensure seamless installation and compliance.


Sustainable & Eco-Friendly Solutions

We use recyclable materials in cable production, aligning with Australia’s Clean Energy initiatives. This commitment to sustainability reduces environmental impact while maintaining product durability.


Efficient OEM & Customization Services

Whether you need custom conductor sizes, insulation tweaks, or branded packaging, our OEM team delivers solutions within short lead times. We collaborate closely with clients to turn technical requirements into tangible products.


FAQ


Is the 0.6/1kV ABC cable suitable for burial installation?

No. This cable is designed exclusively for overhead use and must not be buried—even in conduits. Burial can damage the insulation and compromise safety, leading to performance issues or failures.


Can I request a custom core configuration for my project?

Yes. We offer flexible customization, including 3-core, 4-core, or 5-core setups, plus optional integrated neutral messenger wires. Contact our team to discuss your specific core configuration needs.


What is the maximum ambient temperature the cable can withstand?

The cable operates reliably in ambient temperatures ranging from -40°C to +90°C, with a maximum conductor temperature of 90°C (per IEC standards). This range makes it suitable for Australia’s hot summers and New Zealand’s cold winters.


Code: ABC 0.6/1kV.

Standards:HD 626  S1:1996  Part5-Section D,AMKA(SFS     2200).

Construction: Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral Messenger:Aluminum conductors.

Application: Aerial Bundled Conductors are used for tributary networks of power buildings and their internal networks.

Installation: These cables are not allowed to be buried, even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.4

±0.05

1.4


7.1

7.3

70


25

5.9

±0.02

1.4


8.3

9.1

95


35

6.9

±0.02

1.6


9.7

10.5

115


50

8.1

±0.25

1.6


10.8

11.8

140


70

9.7

±0.25

1.8


12.8

13.8

180


120

12.8

±0.30

2.0


16.2

17.4

250


*  Defined  for  ambient  temperature  of 25℃  and  max.conductor  temperature  of 70℃.

Cross Section

Conductor Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


25

5.9

±0.02



5.5

6.3


7.4

35

6.9

±0.02



6.5

7.3


10.3

50

8.1

±0.25



7.6

8.6


14.2

70

9.7

±0.25



9.2

10.2


20.6

95

11.4

±0.30



10.8

12.0


27.9

Dimensions     of     Cable     Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+ Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

1×16+25

15

3×16+25

22

4×16+25

22

3×25+35

26

4×25+35

26

3×35+50

30

3×50+70

35

3×70+95

41

3×120+95

47

LV-ABC Lines with Insulated Neutral Messenger

Code: ABC 0.6/1kV.

Standards:HD 626 S1:1996 Part 6-Section E,AMKA(SFS 2200)

Construction: Aluminum conductors with XLPE  insulation.

Application:Aerial Bundled Conductors are used for tributary networks of power     buildings and their internal networks.

Installation:These cables are not allowed to be buried,even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameten

Current Carrying Capacity

Breaking Load

(mm²)

min.

max.

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.6

5.1

1.2


7.0

7.8



25

5.8

6.3

1.4


8.6

9.4

112


35

6.8

7.3

1.6


10.0

10.9

138


50

7.9

8.4

1.6


11.1

12.0

168


70

9.7

10.2

1.8


13.3

14.2

213


95

11.0

12.0

1.8


14.6

15.7

258


120

12.0

13.1

1.8


15.6

16.7

306


150

13.9

15.0

1.7


17.3

18.6

344


* Defined for ambient temperature of 30℃ and max. conductor temperature of 90℃.

Dimensions of Neutral Messenger Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


54.6

9.2

9.6

1.6


12.3

13.0


16.6

70

10.0

10.2

1.5


12.9

13.6


20.5

95

12.2

12.9

1.6


15.3

16.3


27.5

* Defined for ambient temperature of 30℃ and max.conductor temperature of 90℃.

Dimensions of Cable Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

3×25+54.6

30.0

3×35+K×16+54.6

33.0

3×50+K×16+54.6

36.0

3×70+K×16+54.6

37.5

3×70+K×25+54.6

40.0

3×70+K×16+70

41.0

3×95+K×16+70

44.0

3×120+K×16+70

46.0

3×120+K×16+95

47.0

3×150+K×16+70

48.0

3×150+K×16+95

49.0

* Note: K number of public lighting conductors(K can be equal to 0.1.2.or 3).

Code: ABC 11kV.

Standards:SANS 1713.

Construction:Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral  Messenger:A  stranded  galvanized  steel  conductor  with  XLPE insulation.

Application: The Aerial Bundled Conductors shall suitable for continuous

operation outdoors in tropical areas at altitudes of up to 2200m above sea

level, humidity of up to 90%, average ambient temperature of+30℃ with

a minimum of - 1℃ and a maximum of +4℃ in direct  sunlight, heavy

saline  conditions  along  the  coast  and  isoceraunic  levels  of up  to  180

thunderstorm days per year.

Installation:These cables are not allowed to be buried,even in conduits.


Phase Conductor Characteristics

1

Conductor    size

mm²

70

95

185

2

Diameter    over    conductor.nominal

mm

9.3-10.2

11.6

16.4


3

Thickness   of   dielectric.nominal

mm

3.4

3.4

3.4

Minimum  at  a  point

mm

2.96

2.96

2.96

4

Diameter  over  insulation.  nominal

mm

16.1-17.0

21.3

25.9

5

Diameter  over  semi-conducting  core  screen.  nominal

mm

18.1-19

23.3

27.9

6

Thickness  of  copper  tape.nominal

mm

0.15

1.15

2.15


7

Thickness   of   sheath.nominal

mm

1.8

1.8

1.8

Minimum  at  a  point

mm

1.43

1.43

1.51

8

Catenary   size

mm²

50

50

70

9

Overall   diameter   of   bundle.nominal

mm

55.7

67.8

79.2

10

Nominal  mass

kg/m

2.64

3.25

4.65


Supporting Catenary Characteristics

1

Catenary size

mm²

50

70

2

Number of wires


7

7

3

Wire size(diameter)

mm

3.0

3.6

4

Minimum tensile strength of each wire

kN

9.26

13.13

5

Elongation at break. minimum

%

3.5

4.0


6

Thickness of protective covering




Nominal

mm

1.2

1.2

Minimum at a point

mm

0.96

1.96

7

Impusewhsandvoag        e1.250s


21kV/5min

21kV/5min


Previous: 
Next: 
Keep In Touch With Us

ABOUT US

Our company is a professional company that engaged in production, sales, technology research, technology development and technical services of electrical system products, power engineering design and construction, electrical products, electrical equipment, sales, installation and technical services of energy storage equipment.
 

PRODUCTS

CONTACT US

  Mainland China Office
2201-7 & 2201-8, Dongjiu Building, No.888 Jiefang East Road, Yixing City, Jiangsu Province, China
  +86-510-87013147
  Hong Kong Office
Flat A,7/F.,Annking Industrial Building,22 Wang Yip Street East,Yuen Long,N.T.,Hong Kong
  +852-2470 1972
​Copyright ©  2025 East Energy Electrical Engineering Co., Ltd.  苏ICP备16064163号-1 Technology by Leadong. Sitemap.