The Aerial Bundled Cable (ABC) is a modern overhead power distribution solution designed to meet IEC 60228 and British Standard BS 7870. It consists of multiple insulated conductors (aluminum or copper) bound together with a durable, UV-stabilized outer binder, forming a compact and weather-resistant assembly. The insulation is made of cross-linked polyethylene (XLPE) or polyethylene (PE), providing excellent electrical strength, thermal stability, and resistance to environmental stress.
Compared to traditional bare overhead conductors, ABC cables significantly improve safety by eliminating the risk of accidental contact with live wires. The bundled structure also allows for narrower right-of-way, lower installation height, and reduced phase-to-phase faults caused by tree branches, debris, or animals. This makes ABC the preferred choice for densely populated areas, coastal regions, mountainous terrain, and industrial zones worldwide.
Fully Insulated Conductors – Eliminates direct contact hazards for people, wildlife, and workers; reduces short circuits caused by external factors.
Compact Bundled Design – Requires less clearance and narrower right-of-way, ideal for space-constrained urban environments.
High Mechanical Strength – Withstands heavy wind, snow, ice loads, and abrasion; UV-stabilized binding prevents long-term degradation.
Compliance with IEC & British Standards – Certified to IEC 60228 (conductors) and BS 7870 (aerial bundled cables), ensuring global grid compatibility.
Low Maintenance & Long Life – Enclosed insulation protects against corrosion, moisture, and chemicals, reducing lifecycle costs.
Thermal Management – XLPE/PE insulation offers high heat resistance, enabling safe operation within rated current limits.
| Parameter | Details |
|---|---|
| Standards | IEC 60228, BS 7870 |
| Voltage Rating | 1 kV – 36 kV (LV to MV) |
| Conductor Material | Aluminum (or copper on request) |
| Insulation Material | XLPE or PE |
| Number of Cores | 2, 3, 4, or custom |
| Operating Temperature | –40°C to +90°C (XLPE) |
| Binding Material | UV-stabilized polymer |
| Applications | Overhead distribution, residential, industrial, coastal, mountainous, railway |
Residential & Urban Areas – Safe overhead power supply near buildings, trees, and pedestrian zones.
Industrial Zones – Reliable performance in dusty, humid, or chemically aggressive environments.
Coastal Regions – Corrosion-resistant materials resist salt spray and high humidity.
Mountainous & Windy Terrain – Bundled structure reduces wind-induced conductor clashing and ice shedding risks.
Railway & Transit Systems – Powers overhead lines for trains and trams with space‑efficient installation.
Certified Quality – Fully compliant with international standards, backed by factory and third-party test reports.
Customizable – Available in different core counts, conductor materials, insulation thickness, and voltage grades.
Easy Installation – Compatible with standard overhead line hardware; minimal retraining required.
Global Export Experience – Trusted by utility companies and contractors in Europe, Asia, Africa, and the Americas.
Q: What voltage range is available for this ABC cable?
A: Our ABC cable is available from 1 kV to 36 kV, covering low-voltage and medium-voltage distribution networks.
Q: Is the binding material UV resistant?
A: Yes, the outer binder is made of UV-stabilized polymer, preventing cracking or weakening from prolonged sunlight exposure.
Q: How does bundling affect thermal performance?
A: The design includes thermal management. XLPE insulation has high heat resistance (up to 90°C continuous), ensuring safe operation within rated current.
Q: Does ABC cable require special installation tools?
A: Standard overhead line tools can be used. However, proper tensioning and spacing techniques are recommended; we provide installation guidelines upon request.
Q: Can I get a custom conductor material (copper) or insulation type?
A: Yes. Copper conductors and PE insulation are available as options. Please specify your requirements when ordering.
| Component | Specification |
|---|---|
| Phase Conductors | Aluminum alloy core + PE/XLPE insulation |
| Neutral Messenger | AAAC or galvanized steel strand (optional) |
| Bundle Design | Self-supporting or neutral-supported variants |
| Optional Cores | Auxiliary cores for lighting/control systems |
Nominal area | Number/Dia. | Insulation thickness |
mm² | mm | mm |
1*16+16 | 7/1.70 | 1.30 |
2*16+16 | 7/1.70 | 1.30 |
3*16+16 | 7/1.70 | 1.30 |
4*16 | 7/1.70 | 1.30 |
1*25+25 | 7/2.10 | 1.30 |
2*25+25 | 7/2.10 | 1.30 |
3*25+25 | 7/2.10 | 1.30 |
4*25 | 7/2.10 | 1.30 |
1*35+35 | 7/2.50 | 1.30 |
Nominal area | Number/Dia. | Insulation thickness |
mm² | mm | mm |
2*35+35 | 7/2.50 | 1.30 |
3*35+35 | 7/2.50 | 1.30 |
4*35 | 7/2.50 | 1.30 |
1*50+50 | 7/3.0 | 1.50 |
3*50+50 | 7/3.0 | 1.50 |
1*70+70 | 19/2.10 | 1.50 |
3*70+70 | 19/2.10 | 1.50 |
3*95+95 | 19/2.50 | 1.60 |


Code: ABC 0.6/1kV.
Standards:HD 626 S1:1996 Part5-Section D,AMKA(SFS 2200).
Construction: Phase Conductors:Aluminum conductors with XLPE insulation.
Neutral Messenger:Aluminum conductors.
Application: Aerial Bundled Conductors are used for tributary networks of power buildings and their internal networks.
Installation: These cables are not allowed to be buried, even in conduits.
Dimensions of Phase Conductors
Cross Section | Conductor Diameter | Thickness of Insulation | Core Diameter | Current Carrying Capacity | Breaking Load | |||
(mm²) | min. | tolerance | nom. | min. | min. | max. | (A*) | (kN) |
(mm) | (mm) | (mm) | (mm) | (mm) | ||||
16 | 4.4 | ±0.05 | 1.4 | 7.1 | 7.3 | 70 | ||
25 | 5.9 | ±0.02 | 1.4 | 8.3 | 9.1 | 95 | ||
35 | 6.9 | ±0.02 | 1.6 | 9.7 | 10.5 | 115 | ||
50 | 8.1 | ±0.25 | 1.6 | 10.8 | 11.8 | 140 | ||
70 | 9.7 | ±0.25 | 1.8 | 12.8 | 13.8 | 180 | ||
120 | 12.8 | ±0.30 | 2.0 | 16.2 | 17.4 | 250 | ||
* Defined for ambient temperature of 25℃ and max.conductor temperature of 70℃.
Cross Section | Conductor Diameter | Thickness of Insulation | Core Diameter | Current Carrying Capacity | Breaking Load | |||
(mm²) | min. | tolerance | nom. | min. | min. | max. | (A*) | (kN) |
(mm) | (mm) | (mm) | (mm) | (mm) | ||||
25 | 5.9 | ±0.02 | 5.5 | 6.3 | 7.4 | |||
35 | 6.9 | ±0.02 | 6.5 | 7.3 | 10.3 | |||
50 | 8.1 | ±0.25 | 7.6 | 8.6 | 14.2 | |||
70 | 9.7 | ±0.25 | 9.2 | 10.2 | 20.6 | |||
95 | 11.4 | ±0.30 | 10.8 | 12.0 | 27.9 | |||
Dimensions of Cable Bundle
Number of Phase Cores× Cross Section +Public Lighting Conductors + Neutral Cross Section (mm²) | Bundle Diameter Approx. (mm) |
1×16+25 | 15 |
3×16+25 | 22 |
4×16+25 | 22 |
3×25+35 | 26 |
4×25+35 | 26 |
3×35+50 | 30 |
3×50+70 | 35 |
3×70+95 | 41 |
3×120+95 | 47 |
LV-ABC Lines with Insulated Neutral Messenger
Code: ABC 0.6/1kV.
Standards:HD 626 S1:1996 Part 6-Section E,AMKA(SFS 2200)
Construction: Aluminum conductors with XLPE insulation.
Application:Aerial Bundled Conductors are used for tributary networks of power buildings and their internal networks.
Installation:These cables are not allowed to be buried,even in conduits.
Dimensions of Phase Conductors
Cross Section | Conductor Diameter | Thickness of Insulation | Core Diameten | Current Carrying Capacity | Breaking Load | |||
(mm²) | min. | max. | nom. | min. | min. | max. | (A*) | (kN) |
(mm) | (mm) | (mm) | (mm) | (mm) | ||||
16 | 4.6 | 5.1 | 1.2 | 7.0 | 7.8 | |||
25 | 5.8 | 6.3 | 1.4 | 8.6 | 9.4 | 112 | ||
35 | 6.8 | 7.3 | 1.6 | 10.0 | 10.9 | 138 | ||
50 | 7.9 | 8.4 | 1.6 | 11.1 | 12.0 | 168 | ||
70 | 9.7 | 10.2 | 1.8 | 13.3 | 14.2 | 213 | ||
95 | 11.0 | 12.0 | 1.8 | 14.6 | 15.7 | 258 | ||
120 | 12.0 | 13.1 | 1.8 | 15.6 | 16.7 | 306 | ||
150 | 13.9 | 15.0 | 1.7 | 17.3 | 18.6 | 344 | ||
* Defined for ambient temperature of 30℃ and max. conductor temperature of 90℃.
Dimensions of Neutral Messenger Conductors
Cross Section | Conductor Diameter | Thickness of Insulation | Core Diameter | Current Carrying Capacity | Breaking Load | |||
(mm²) | min. | tolerance | nom. | min. | min. | max. | (A*) | (kN) |
(mm) | (mm) | (mm) | (mm) | (mm) | ||||
54.6 | 9.2 | 9.6 | 1.6 | 12.3 | 13.0 | 16.6 | ||
70 | 10.0 | 10.2 | 1.5 | 12.9 | 13.6 | 20.5 | ||
95 | 12.2 | 12.9 | 1.6 | 15.3 | 16.3 | 27.5 | ||
* Defined for ambient temperature of 30℃ and max.conductor temperature of 90℃.
Dimensions of Cable Bundle
Number of Phase Cores× Cross Section +Public Lighting Conductors +Neutral Cross Section (mm²) | Bundle Diameter Approx. (mm) |
3×25+54.6 | 30.0 |
3×35+K×16+54.6 | 33.0 |
3×50+K×16+54.6 | 36.0 |
3×70+K×16+54.6 | 37.5 |
3×70+K×25+54.6 | 40.0 |
3×70+K×16+70 | 41.0 |
3×95+K×16+70 | 44.0 |
3×120+K×16+70 | 46.0 |
3×120+K×16+95 | 47.0 |
3×150+K×16+70 | 48.0 |
3×150+K×16+95 | 49.0 |
* Note: K number of public lighting conductors(K can be equal to 0.1.2.or 3).
Code: ABC 11kV.
Standards:SANS 1713.
Construction:Phase Conductors:Aluminum conductors with XLPE insulation.
Neutral Messenger:A stranded galvanized steel conductor with XLPE insulation.
Application: The Aerial Bundled Conductors shall suitable for continuous
operation outdoors in tropical areas at altitudes of up to 2200m above sea
level, humidity of up to 90%, average ambient temperature of+30℃ with
a minimum of - 1℃ and a maximum of +4℃ in direct sunlight, heavy
saline conditions along the coast and isoceraunic levels of up to 180
thunderstorm days per year.
Installation:These cables are not allowed to be buried,even in conduits.
Phase Conductor Characteristics
1 | Conductor size | mm² | 70 | 95 | 185 |
2 | Diameter over conductor.nominal | mm | 9.3-10.2 | 11.6 | 16.4 |
3 | Thickness of dielectric.nominal | mm | 3.4 | 3.4 | 3.4 |
Minimum at a point | mm | 2.96 | 2.96 | 2.96 | |
4 | Diameter over insulation. nominal | mm | 16.1-17.0 | 21.3 | 25.9 |
5 | Diameter over semi-conducting core screen. nominal | mm | 18.1-19 | 23.3 | 27.9 |
6 | Thickness of copper tape.nominal | mm | 0.15 | 1.15 | 2.15 |
7 | Thickness of sheath.nominal | mm | 1.8 | 1.8 | 1.8 |
Minimum at a point | mm | 1.43 | 1.43 | 1.51 | |
8 | Catenary size | mm² | 50 | 50 | 70 |
9 | Overall diameter of bundle.nominal | mm | 55.7 | 67.8 | 79.2 |
10 | Nominal mass | kg/m | 2.64 | 3.25 | 4.65 |
Supporting Catenary Characteristics
1 | Catenary size | mm² | 50 | 70 |
2 | Number of wires | 7 | 7 | |
3 | Wire size(diameter) | mm | 3.0 | 3.6 |
4 | Minimum tensile strength of each wire | kN | 9.26 | 13.13 |
5 | Elongation at break. minimum | % | 3.5 | 4.0 |
6 | Thickness of protective covering | |||
Nominal | mm | 1.2 | 1.2 | |
Minimum at a point | mm | 0.96 | 1.96 | |
7 | Impusewhsandvoag e1.250s | 21kV/5min | 21kV/5min |