Home » Products » Cables » Power Cable » ABC Overhead Power Cable, 0.6/1kV, IEC & British Standards

ABC Overhead Power Cable, 0.6/1kV, IEC & British Standards

5 0 Reviews
This 0.6/1kV Aerial Bundled Cable (ABC) meets stringent British and IEC standards, offering a robust solution for architectural and urban overhead power systems. Designed for safety and adaptability, it integrates seamlessly into environments requiring minimal visual impact and maximum reliability.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button


Product Overview

The NYY power cable is a PVC‑insulated and PVC‑sheathed cable designed for 0.6/1 kV applications. It is widely used for fixed installations in industrial, commercial, and residential settings.

This cable complies with multiple international standards including IEC 60502, VDE 0276‑603, BS 6346, and TSIEC 60502.


Product Construction – Multi‑Layer Structure

Layer Material Function
Conductor Solid or stranded copper Excellent electrical conductivity + mechanical strength
Insulation PVC Electrical isolation, moisture & chemical resistance
Filling PVC Maintains structural stability, prevents internal shifting
Outer Sheath PVC Protection against mechanical stress, corrosion, environmental factors

Conductor options:

  • Solid conductors – ideal for applications requiring rigidity

  • Stranded conductors – flexibility for installations with bending requirements


Technical Specifications

Parameter Value
Rated voltage 0.6/1 kV
Maximum operating temperature 70°C
Short‑circuit temperature 160°C
Compliance standards IEC 60502, VDE 0276‑603, BS 6346, TSIEC 60502

Cable Parameters Tables

1‑Core NYY Cables

mm² Wire Dia. (mm) Insulation Thick. (mm) Sheath Thick. (mm) DC Res. (Ω/km) Weight (kg/km) Current (Pipe A) Current (Air A)
1×4 2.19 1.0 1.4 4.61 87.0 45 37
1×6 2.68 1.0 1.4 3.08 109 57 48
1×10 7×1.32 1.0 1.4 1.83 166 78 66
1×16 7×1.68 1.0 1.4 1.15 234 103 89
1×25 7×2.19 1.2 1.4 0.727 341 137 118

2‑Core NYY Cables

mm² Wire Dia. (mm) Insulation Thick. (mm) Sheath Thick. (mm) DC Res. (Ω/km) Weight (kg/km) Current (Pipe A) Current (Air A)
2×1.5 1.35 0.8 1.8 12.1 127 32 20
2×2.5 1.73 0.8 1.8 7.41 160 42 27
2×4 2.19 1.0 1.8 4.61 233 54 37
2×6 2.68 1.0 1.8 3.08 295 68 48
2×10 7×1.32 1.0 1.8 1.83 469 90 66
2×16 7×1.68 1.0 1.8 1.15 652 116 89

3‑Core NYY Cables

mm² Wire Dia. (mm) Insulation Thick. (mm) Sheath Thick. (mm) DC Res. (Ω/km) Weight (kg/km) Current (Pipe A) Current (Air A)
3×1.5 1.35 0.8 1.8 12.1 148 26 18
3×2.5 1.73 0.8 1.8 7.41 191 34 25
3×4 2.19 1.0 1.8 4.61 280 44 34
3×6 2.68 1.0 1.8 3.08 361 56 43
3×10 7×1.32 1.0 1.8 1.83 579 75 60
3×16 7×1.68 1.0 1.8 1.15 820 98 80

4‑Core NYY Cables

mm² Wire Dia. (mm) Insulation Thick. (mm) Sheath Thick. (mm) DC Res. (Ω/km) Weight (kg/km) Current (Pipe A) Current (Air A)
4×1.5 1.35 0.8 1.8 12.1 178 26 18
4×2.5 1.73 0.8 1.8 7.41 241 34 25
4×4 2.19 1.0 1.8 4.61 246 44 34
4×6 2.68 1.0 1.8 3.08 456 56 43
4×10 7×1.32 1.0 1.8 1.83 731 75 60
4×16 7×1.68 1.0 1.8 1.15 1036 98 80

5‑Core NYY Cables

mm² Wire Dia. (mm) Insulation Thick. (mm) Sheath Thick. (mm) DC Res. (Ω/km) Weight (kg/km) Current (Pipe A) Current (Air A)
5×1.5 1.35 0.8 1.8 12.1 218 26 18
5×2.5 1.73 0.8 1.8 7.41 285 34 25
5×4 2.19 1.0 1.8 4.61 375 44 34
5×6 2.68 1.0 1.8 3.08 548 56 43
5×10 7×1.32 1.0 1.8 1.83 891 75 60
5×16 7×1.66 1.0 1.8 1.15 1276 98 80

Application Scenarios

Application Description
Indoor Installations Commercial buildings, offices, residential complexes – stable power distribution
Cable Ducts & Industrial Plants Withstands operational demands of machinery and equipment
Switching Stations Robust design for electrical safety and performance
Underground Installations Suitable with additional protection where mechanical damage risk is low

Why Choose This NYY Power Cable?

Benefit Description
Rated voltage 0.6/1 kV
Maximum operating temperature 70°C (short‑circuit up to 160°C)
Standards compliance IEC 60502, VDE 0276‑603, BS 6346, TSIEC 60502
Conductor options Solid or stranded copper
Core configurations 1‑core, 2‑core, 3‑core, 4‑core, 5‑core
Cross‑section range From 1.5 mm² to 25 mm² (larger sizes available upon request)
Current ratings Provided for both pipe and air installations

FAQ (High Search Volume)

Q: What does NYY cable stand for?
A: NYY is a standard designation for PVC‑insulated and PVC‑sheathed power cable rated at 0.6/1 kV, commonly used for fixed installations.

Q: What standards does this cable comply with?
A: It complies with IEC 60502, VDE 0276‑603, BS 6346, and TSIEC 60502.

Q: What is the maximum operating temperature?
A: Normal operation: 70°C. Short‑circuit condition: 160°C.

Q: Can I get solid or stranded conductors?
A: Yes. Both solid and stranded copper conductors are available.

Q: Is this cable suitable for underground installation?
A: Yes, it is suitable for underground installation where the risk of mechanical damage is low. Additional mechanical protection may be required in high‑risk areas.

Q: What core configurations are available?
A: 1‑core, 2‑core, 3‑core, 4‑core, and 5‑core configurations are available as standard.

Q: What is the cross‑sectional area range?
A: From 1.5 mm² to 25 mm² in the standard tables. Larger sizes are available upon request.


Manufacturer Information

East Energy Electrical Engineering Co., Ltd. (China‑based) specializes in:

  • Production, sales, and technical development of electrical system products

  • Power engineering design

  • Construction and installation of energy storage equipment

  • Comprehensive support for clients worldwide





application

packing


Code: ABC 0.6/1kV.

Standards:HD 626  S1:1996  Part5-Section D,AMKA(SFS     2200).

Construction: Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral Messenger:Aluminum conductors.

Application: Aerial Bundled Conductors are used for tributary networks of power buildings and their internal networks.

Installation: These cables are not allowed to be buried, even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.4

±0.05

1.4


7.1

7.3

70


25

5.9

±0.02

1.4


8.3

9.1

95


35

6.9

±0.02

1.6


9.7

10.5

115


50

8.1

±0.25

1.6


10.8

11.8

140


70

9.7

±0.25

1.8


12.8

13.8

180


120

12.8

±0.30

2.0


16.2

17.4

250


*  Defined  for  ambient  temperature  of 25℃  and  max.conductor  temperature  of 70℃.

Cross Section

Conductor Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


25

5.9

±0.02



5.5

6.3


7.4

35

6.9

±0.02



6.5

7.3


10.3

50

8.1

±0.25



7.6

8.6


14.2

70

9.7

±0.25



9.2

10.2


20.6

95

11.4

±0.30



10.8

12.0


27.9

Dimensions     of     Cable     Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+ Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

1×16+25

15

3×16+25

22

4×16+25

22

3×25+35

26

4×25+35

26

3×35+50

30

3×50+70

35

3×70+95

41

3×120+95

47

LV-ABC Lines with Insulated Neutral Messenger

Code: ABC 0.6/1kV.

Standards:HD 626 S1:1996 Part 6-Section E,AMKA(SFS 2200)

Construction: Aluminum conductors with XLPE  insulation.

Application:Aerial Bundled Conductors are used for tributary networks of power     buildings and their internal networks.

Installation:These cables are not allowed to be buried,even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameten

Current Carrying Capacity

Breaking Load

(mm²)

min.

max.

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.6

5.1

1.2


7.0

7.8



25

5.8

6.3

1.4


8.6

9.4

112


35

6.8

7.3

1.6


10.0

10.9

138


50

7.9

8.4

1.6


11.1

12.0

168


70

9.7

10.2

1.8


13.3

14.2

213


95

11.0

12.0

1.8


14.6

15.7

258


120

12.0

13.1

1.8


15.6

16.7

306


150

13.9

15.0

1.7


17.3

18.6

344


* Defined for ambient temperature of 30℃ and max. conductor temperature of 90℃.

Dimensions of Neutral Messenger Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


54.6

9.2

9.6

1.6


12.3

13.0


16.6

70

10.0

10.2

1.5


12.9

13.6


20.5

95

12.2

12.9

1.6


15.3

16.3


27.5

* Defined for ambient temperature of 30℃ and max.conductor temperature of 90℃.

Dimensions of Cable Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

3×25+54.6

30.0

3×35+K×16+54.6

33.0

3×50+K×16+54.6

36.0

3×70+K×16+54.6

37.5

3×70+K×25+54.6

40.0

3×70+K×16+70

41.0

3×95+K×16+70

44.0

3×120+K×16+70

46.0

3×120+K×16+95

47.0

3×150+K×16+70

48.0

3×150+K×16+95

49.0

* Note: K number of public lighting conductors(K can be equal to 0.1.2.or 3).

Code: ABC 11kV.

Standards:SANS 1713.

Construction:Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral  Messenger:A  stranded  galvanized  steel  conductor  with  XLPE insulation.

Application: The Aerial Bundled Conductors shall suitable for continuous

operation outdoors in tropical areas at altitudes of up to 2200m above sea

level, humidity of up to 90%, average ambient temperature of+30℃ with

a minimum of - 1℃ and a maximum of +4℃ in direct  sunlight, heavy

saline  conditions  along  the  coast  and  isoceraunic  levels  of up  to  180

thunderstorm days per year.

Installation:These cables are not allowed to be buried,even in conduits.


Phase Conductor Characteristics

1

Conductor    size

mm²

70

95

185

2

Diameter    over    conductor.nominal

mm

9.3-10.2

11.6

16.4


3

Thickness   of   dielectric.nominal

mm

3.4

3.4

3.4

Minimum  at  a  point

mm

2.96

2.96

2.96

4

Diameter  over  insulation.  nominal

mm

16.1-17.0

21.3

25.9

5

Diameter  over  semi-conducting  core  screen.  nominal

mm

18.1-19

23.3

27.9

6

Thickness  of  copper  tape.nominal

mm

0.15

1.15

2.15


7

Thickness   of   sheath.nominal

mm

1.8

1.8

1.8

Minimum  at  a  point

mm

1.43

1.43

1.51

8

Catenary   size

mm²

50

50

70

9

Overall   diameter   of   bundle.nominal

mm

55.7

67.8

79.2

10

Nominal  mass

kg/m

2.64

3.25

4.65


Supporting Catenary Characteristics

1

Catenary size

mm²

50

70

2

Number of wires


7

7

3

Wire size(diameter)

mm

3.0

3.6

4

Minimum tensile strength of each wire

kN

9.26

13.13

5

Elongation at break. minimum

%

3.5

4.0


6

Thickness of protective covering




Nominal

mm

1.2

1.2

Minimum at a point

mm

0.96

1.96

7

Impusewhsandvoag        e1.250s


21kV/5min

21kV/5min


Previous: 
Next: 
Keep In Touch With Us

ABOUT US

Our company is a professional company that engaged in production, sales, technology research, technology development and technical services of electrical system products, power engineering design and construction, electrical products, electrical equipment, sales, installation and technical services of energy storage equipment.
 

PRODUCTS

CONTACT US

  Mainland China Office
2201-7 & 2201-8, Dongjiu Building, No.888 Jiefang East Road, Yixing City, Jiangsu Province, China
  +86 18761555908
  +86-510-87013147
​Copyright ©  2025 East Energy Electrical Engineering Co., Ltd.  苏ICP备16064163号-1 Technology by Leadong. Sitemap.