ABC Overhead Power Cable, 0.6/1kV, IEC & British Standards

5 0 Reviews
This 0.6/1kV Aerial Bundled Cable (ABC) meets stringent British and IEC standards, offering a robust solution for architectural and urban overhead power systems. Designed for safety and adaptability, it integrates seamlessly into environments requiring minimal visual impact and maximum reliability.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button


Aerial Bundled Cable (ABC) – IEC & British Standard Compliant

Product Description

The Aerial Bundled Cable (ABC) compliant with IEC and British Standards is a revolutionary overhead power distribution solution designed for safe and efficient electricity transmission in densely populated areas.

This cable system consists of multiple insulated conductors bound together with a durable outer binding, creating a compact, weather-resistant assembly that minimizes the risk of accidental contact and short circuits.

The conductors are typically made of high-purity aluminum or copper, depending on application requirements, and are insulated with:

  • Cross-linked polyethylene (XLPE) – for superior electrical and mechanical properties

  • Polyethylene (PE) – for cost-effective performance

Compliance Standards

Standard Description
IEC 60228 Conductors of insulated cables
BS 7870 Aerial bundled cables for overhead distribution

This ensures compatibility with global power grids while adhering to strict safety and performance criteria.

Key Design Benefits

  • Reduced need for additional insulation between phases

  • Closer conductor spacing – space-efficient installations

  • Ideal for urban settings where overhead lines coexist with:

    • Buildings

    • Trees

    • Other infrastructure


Key Features

Enhanced Safety

  • Fully insulated conductors eliminate direct contact risk

  • Reduces electrical accidents for:

    • Pedestrians

    • Workers

    • Wildlife

  • Minimizes phase-to-phase faults caused by:

    • Tree branches

    • Debris

    • External factors

Space Optimization

  • Compact bundled structure allows for narrower right-of-way requirements

  • Ideal for urban areas with limited space

  • Can be installed at lower heights than traditional open-conductor systems

  • Improves aesthetic compatibility with urban landscapes

High Mechanical Strength

  • Binding material withstands:

    • Strong winds

    • Heavy snow

    • Ice loads

  • Insulated conductors resist:

    • Abrasion

    • Chemical corrosion

  • Extended service life

Compliance with Standards

  • Certified to IEC and British Standards

  • Rigorous testing for:

    • Electrical conductivity

    • Insulation resistance

    • Flame retardancy

Low Maintenance

  • Fully enclosed design reduces:

    • Frequent inspections

    • Repairs

  • Insulation protects conductors from environmental damage

  • Lower lifecycle costs compared to traditional overhead lines


Applications

Application Description
Residential Areas Safe power distribution, minimizes accident risk from falling branches or building contact
Industrial Zones Reliable power for factories and heavy machinery – withstands dust, moisture, chemical vapors
Coastal Regions Corrosion-resistant insulation and binding – suitable for high-salt air environments
Mountainous / Terrain-Challenged Areas Bundled design reduces impact of strong winds and uneven terrain
Railway & Transit Systems Powers overhead lines for trains and trams – safe, space-efficient solution

Technical Specifications

Conductor Construction

Nominal Area (mm²) Number/Dia. (mm) Insulation Thickness (mm)
1×16+16 7/1.70 1.30
2×16+16 7/1.70 1.30
3×16+16 7/1.70 1.30
4×16 7/1.70 1.30
1×25+25 7/2.10 1.30
2×25+25 7/2.10 1.30
3×25+25 7/2.10 1.30
4×25 7/2.10 1.30
1×35+35 7/2.50 1.30
2×35+35 7/2.50 1.30
3×35+35 7/2.50 1.30
4×35 7/2.50 1.30
1×50+50 7/3.0 1.50
3×50+50 7/3.0 1.50
1×70+70 19/2.10 1.50
3×70+70 19/2.10 1.50
3×95+95 19/2.50 1.60

Component Summary

Component Specification
Phase Conductors Aluminum alloy core + PE/XLPE insulation
Neutral Messenger AAAC or galvanized steel strand (optional)
Bundle Design Self-supporting or neutral-supported variants
Optional Cores Auxiliary cores for lighting/control systems

FAQ

Q: Can the ABC system be used for both low- and high-voltage applications?
A: Yes. It is available in voltage classes ranging from 1kV to 36kV, suitable for distribution networks in various settings.

Q: How does the bundling affect the cable's thermal performance?
A: The design includes thermal management considerations, and the insulation materials have high heat resistance to ensure safe operation within rated current limits.

Q: Is the binding material UV-resistant?
A: Yes. The binding is made from UV-stabilized polymers that prevent degradation from prolonged sunlight exposure, ensuring long-term structural integrity.

Q: Does the ABC system require special installation equipment?
A: Standard overhead line installation tools can be used, though training on bundling techniques is recommended to ensure proper conductor spacing and tensioning.

application

packing


Code: ABC 0.6/1kV.

Standards:HD 626  S1:1996  Part5-Section D,AMKA(SFS     2200).

Construction: Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral Messenger:Aluminum conductors.

Application: Aerial Bundled Conductors are used for tributary networks of power buildings and their internal networks.

Installation: These cables are not allowed to be buried, even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.4

±0.05

1.4


7.1

7.3

70


25

5.9

±0.02

1.4


8.3

9.1

95


35

6.9

±0.02

1.6


9.7

10.5

115


50

8.1

±0.25

1.6


10.8

11.8

140


70

9.7

±0.25

1.8


12.8

13.8

180


120

12.8

±0.30

2.0


16.2

17.4

250


*  Defined  for  ambient  temperature  of 25℃  and  max.conductor  temperature  of 70℃.

Cross Section

Conductor Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


25

5.9

±0.02



5.5

6.3


7.4

35

6.9

±0.02



6.5

7.3


10.3

50

8.1

±0.25



7.6

8.6


14.2

70

9.7

±0.25



9.2

10.2


20.6

95

11.4

±0.30



10.8

12.0


27.9

Dimensions     of     Cable     Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+ Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

1×16+25

15

3×16+25

22

4×16+25

22

3×25+35

26

4×25+35

26

3×35+50

30

3×50+70

35

3×70+95

41

3×120+95

47

LV-ABC Lines with Insulated Neutral Messenger

Code: ABC 0.6/1kV.

Standards:HD 626 S1:1996 Part 6-Section E,AMKA(SFS 2200)

Construction: Aluminum conductors with XLPE  insulation.

Application:Aerial Bundled Conductors are used for tributary networks of power     buildings and their internal networks.

Installation:These cables are not allowed to be buried,even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameten

Current Carrying Capacity

Breaking Load

(mm²)

min.

max.

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.6

5.1

1.2


7.0

7.8



25

5.8

6.3

1.4


8.6

9.4

112


35

6.8

7.3

1.6


10.0

10.9

138


50

7.9

8.4

1.6


11.1

12.0

168


70

9.7

10.2

1.8


13.3

14.2

213


95

11.0

12.0

1.8


14.6

15.7

258


120

12.0

13.1

1.8


15.6

16.7

306


150

13.9

15.0

1.7


17.3

18.6

344


* Defined for ambient temperature of 30℃ and max. conductor temperature of 90℃.

Dimensions of Neutral Messenger Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


54.6

9.2

9.6

1.6


12.3

13.0


16.6

70

10.0

10.2

1.5


12.9

13.6


20.5

95

12.2

12.9

1.6


15.3

16.3


27.5

* Defined for ambient temperature of 30℃ and max.conductor temperature of 90℃.

Dimensions of Cable Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

3×25+54.6

30.0

3×35+K×16+54.6

33.0

3×50+K×16+54.6

36.0

3×70+K×16+54.6

37.5

3×70+K×25+54.6

40.0

3×70+K×16+70

41.0

3×95+K×16+70

44.0

3×120+K×16+70

46.0

3×120+K×16+95

47.0

3×150+K×16+70

48.0

3×150+K×16+95

49.0

* Note: K number of public lighting conductors(K can be equal to 0.1.2.or 3).

Code: ABC 11kV.

Standards:SANS 1713.

Construction:Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral  Messenger:A  stranded  galvanized  steel  conductor  with  XLPE insulation.

Application: The Aerial Bundled Conductors shall suitable for continuous

operation outdoors in tropical areas at altitudes of up to 2200m above sea

level, humidity of up to 90%, average ambient temperature of+30℃ with

a minimum of - 1℃ and a maximum of +4℃ in direct  sunlight, heavy

saline  conditions  along  the  coast  and  isoceraunic  levels  of up  to  180

thunderstorm days per year.

Installation:These cables are not allowed to be buried,even in conduits.


Phase Conductor Characteristics

1

Conductor    size

mm²

70

95

185

2

Diameter    over    conductor.nominal

mm

9.3-10.2

11.6

16.4


3

Thickness   of   dielectric.nominal

mm

3.4

3.4

3.4

Minimum  at  a  point

mm

2.96

2.96

2.96

4

Diameter  over  insulation.  nominal

mm

16.1-17.0

21.3

25.9

5

Diameter  over  semi-conducting  core  screen.  nominal

mm

18.1-19

23.3

27.9

6

Thickness  of  copper  tape.nominal

mm

0.15

1.15

2.15


7

Thickness   of   sheath.nominal

mm

1.8

1.8

1.8

Minimum  at  a  point

mm

1.43

1.43

1.51

8

Catenary   size

mm²

50

50

70

9

Overall   diameter   of   bundle.nominal

mm

55.7

67.8

79.2

10

Nominal  mass

kg/m

2.64

3.25

4.65


Supporting Catenary Characteristics

1

Catenary size

mm²

50

70

2

Number of wires


7

7

3

Wire size(diameter)

mm

3.0

3.6

4

Minimum tensile strength of each wire

kN

9.26

13.13

5

Elongation at break. minimum

%

3.5

4.0


6

Thickness of protective covering




Nominal

mm

1.2

1.2

Minimum at a point

mm

0.96

1.96

7

Impusewhsandvoag        e1.250s


21kV/5min

21kV/5min


Previous: 
Next: 
Keep In Touch With Us

ABOUT US

Our company is a professional company that engaged in production, sales, technology research, technology development and technical services of electrical system products, power engineering design and construction, electrical products, electrical equipment, sales, installation and technical services of energy storage equipment.
 

PRODUCTS

CONTACT US

  Mainland China Office
2201-7 & 2201-8, Dongjiu Building, No.888 Jiefang East Road, Yixing City, Jiangsu Province, China
  +86-510-87013147
  Hong Kong Office
Flat A,7/F.,Annking Industrial Building,22 Wang Yip Street East,Yuen Long,N.T.,Hong Kong
  +852-84960208
​Copyright ©  2025 East Energy Electrical Engineering Co., Ltd.  苏ICP备16064163号-1 Technology by Leadong. Sitemap.