Halogen Free H07Z-U/R Power Wire 450/750V with Copper Conductor for Enhanced Safety

5 0 Reviews
This Halogen Free H07Z-U/R Power Wire is a single-core cable with a copper conductor and a thermoplastic halogen-free insulation, rated 450/750V. It is designed for fixed installations in public buildings, tunnels, underground stations, hospitals, and other areas where fire safety and low smoke emission are critical. The H07Z-U version uses a solid copper conductor, while the H07Z-R version uses a flexible stranded conductor for easier routing. The insulation contains no halogens, so it does not release toxic or corrosive gases when exposed to fire, and it produces limited smoke. For procurement, the main value is compliance with strict fire safety standards, reliable electrical performance, and suitability for indoor wiring in safety-sensitive environments.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

How to Select the Right Halogen Free H07Z-U/R Power Wire

1. Voltage Rating

Confirm the system voltage does not exceed the cable rating:

  • H07Z-U/R: 450/750V (U₀/U), suitable for low-voltage power and control circuits.
    For three-phase 400V systems, 450/750V is standard. For lower-voltage control circuits, this rating provides adequate margin.

2. Conductor Type: Solid vs. Stranded

  • H07Z-U (solid): Suitable for fixed installations where the cable is not subject to movement or repeated bending. Easier to terminate in some terminal types.

  • H07Z-R (stranded, flexible): Better for routing through conduits with bends, and for connections requiring some flexibility during installation. Not intended for continuous flexing; use H07Z-K for higher flexibility.
    Select U for simple fixed wiring; select R when installation requires easier pulling and bending.

3. Cross-Sectional Area

Choose the conductor size based on:

  • Continuous load current

  • Permissible voltage drop

  • Ambient temperature and grouping

  • Short-circuit withstand
    Typical range: 0.5 mm² to 240 mm². Common sizes for panel and building wiring: 1.5, 2.5, 4, 6, 10, 16, 25, 35 mm².

4. Insulation Material and Temperature

  • Halogen-free thermoplastic insulation: Rated 70°C continuous conductor temperature.

  • Low smoke and zero halogen: Meets IEC 60754 (halogen acid gas) and IEC 61034 (smoke density) when tested.

  • Flame retardant: Complies with IEC 60332-1 for single cable vertical flame propagation.
    Confirm that the selected product meets the specific fire performance requirements of the project.

5. Installation Environment

  • Public buildings and high-occupancy areas: Required where toxic gas and smoke emission must be minimized.

  • Tunnels, underground stations, and enclosed spaces: Low smoke emission aids evacuation and firefighting.

  • Hospitals, schools, data centers: Protect sensitive equipment and people from corrosive gases.

  • Outdoor or wet locations: H07Z-U/R is primarily for indoor fixed installations. For outdoor or wet areas, confirm suitability or consider alternative insulation.

  • High-temperature areas: Verify ambient temperature against the 70°C conductor limit.

6. Bending Radius

  • Fixed installation: Typically 4 × outer diameter for unarmoured cable.

  • During installation: Avoid sharp bends that could damage insulation.

7. Color Coding

Select colors for phase, neutral, and protective earth:

  • Phase: Black, brown, grey.

  • Neutral: Blue.

  • Protective earth: Green/yellow.

  • Other: Red, white, orange for control or signal wiring.
    Confirm against local wiring codes and project specifications.

8. Standards and Approvals

  • H07Z-U/R: EN 50525-3-31, IEC 60227 (where applicable), VDE 0281-9.

  • Halogen-free: IEC 60754-1/2.

  • Smoke density: IEC 61034-1/2.

  • Flame retardance: IEC 60332-1.

  • RoHS / REACH: Confirm compliance if required.
    Request test reports or certificates of conformity as needed.

9. Packaging and Length

  • Coils: 100 m, 200 m, or custom.

  • Drums: For larger cross-sections or long lengths.

  • Cut lengths: Pre-cut with ferrules or terminals if required.
    Confirm packaging to protect insulation during transport and storage.


Technical Specifications

ParameterUnitTypical Range / Option
Standard—EN 50525-3-31, VDE 0281-9
Type—H07Z-U (solid) / H07Z-R (stranded), single-core
Rated Voltage U₀/UV450/750
Conductor—Plain copper, Class 1 (solid) or Class 2 (stranded)
Insulation—Halogen-free thermoplastic
Conductor Temperature°C70 (continuous)
Ambient Temperature°C-15 to +70 (fixed installation)
Cross-Section Rangemm²0.5 – 240
Outer DiametermmDepends on cross-section
Bending Radius (fixed)—≥ 4 × outer diameter
Halogen Content—Zero halogen per IEC 60754
Smoke Density—Low smoke per IEC 61034
Flame Retardance—IEC 60332-1
Color—Black, blue, brown, grey, green/yellow, red, white, orange, custom
Packaging—Coil, drum, cut length
Lengthm100, 200, 500, 1000, custom
RoHS / REACH—Available on request

Note: Specifications vary by manufacturer and standard. Confirm actual dimensions, temperature rating, and approvals before ordering.


Typical Applications

  • Public buildings: airports, railway stations, shopping centers

  • Tunnels, underground passages, and enclosed parking areas

  • Hospitals, schools, and other high-occupancy facilities

  • Data centers and telecommunication rooms

  • Control panels and distribution boards requiring low smoke

  • Emergency lighting and fire alarm circuits

  • Fixed wiring in areas where halogen-free cable is specified



H07Z-U/R

450/750V

Code:H07Z-U/R

Standard:CENELEC HD 22.9.BS 7211

Construcion:1-Solid or stranded copper conductor

                      2-Special LSFOH thermosetting insulation


Application:Places where there is risk of fire and crowded places like shopping malls, business centers, hotels,

schools, tunnels etc.

Technical Data:Max.operating temperature 70℃


Nominal

Cross

section

Number and

Dia.of wires

Thickness

of insulation

Average Overall Diameter

Approx Total Weight

Conductor DC resistance at

20℃

Mas. Current

Carrying

Capacity at 30℃

mm²

No. ×mm

mm

mm

Kg/km

Ω/km

Air A

H⁰7Z-U

1.5

1.35

0.7

2.8

20.0

12.1

25

2.5

1.73

0.8

3.4

31.2

7.41

34

4

2.19

0.8

3.8

45.1

4.61

45

6

2.68

0.8

4.3

63.8

3.08

57

H⁰7Z-R

1.5

7×0.51

0.7

3.0

21.5

12.1

25

2.5

7×0.66

0.8

3.6

32.9

7.41

34

4

7×0.83

0.8

4.1

47.7

4.61

45

6

7×1.02

0.8

4.7

67.8

3.08

57

10

7×1.34

1.0

5.9

109.2

1.83

75

16

7×1.70

1.0

7.0

167.6

1.15

100

25

7×2.20

1.2

8.4

262.3

0.727

130

35

7×2.55

1.2

9.4

348.1

0.524

160

50

7×3.00

1.4

10.9

471.6

0.387

200


Previous: 
Next: 
Keep In Touch With Us

ABOUT US

Our company is a professional company that engaged in production, sales, technology research, technology development and technical services of electrical system products, power engineering design and construction, electrical products, electrical equipment, sales, installation and technical services of energy storage equipment.
 

PRODUCTS

CONTACT US

  Mainland China Office
Yixing Office( Head Quater) 
2201-7 & 2201-8, Dongjiu Building, No.888 Jiefang East Road, Yixing City, Jiangsu Province, China
Wuxi Office
 Room 2207, Building 6, Finance 3rd Street, Taihu Subdistrict, Binhu District, Wuxi City (Jiaye International City), Jiangsu Province, China
  +86 18020528228
  +86-510-87013147
​Copyright ©  2025 East Energy Electrical Engineering Co., Ltd.  苏ICP备16064163号-1 Technology by Leadong. Sitemap.
 Hong Kong Office
Flat A,7/F.,Annking industrial Building,22 Wang Yip Street East,Yuen Long,N.T.,Hong Kong
  +852 84960208
  Hong Kong Office
Flat A,7/F.,Annking industrial Building,22 Wang Yip Street East,Yuen Long,N.T.,Hong Kong
  +852 84960208